NEKTRA 3291019 Installation Manual Download Page 10

4

 Joist mounting installation

1. Preparation for mounting 

 

 

Determine thickness* of finished ceiling board. 

 

Place main body (A) against ceiling joist in desired location. 

 

Ensure bottom of main body (A) hangs down below joist to account  
for finished ceiling board. 

NOTE:

If thickness of finished ceiling board is 3/4" (1.9 cm) then main body (A) 
should hang down from joist 3/4" (1.9 cm). 

2. Mounting fan body 

 

 

Use wood screws (BB) to loosely attach both sides of main body  
to joist. 

 

Ensure ventilation fan is level and that proper clearance is given  
for finished ceiling board. 

 

When main body (A) is level and in the intended location, tighten 
screws (BB) on both side of it.

   

Safety information and warnings

 

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, 
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

16.  Use this unit in the manner intended by the manufacturer. If you have 

any questions, please call customer service.

17.  Installation work and electrical wiring must be done by a qualifed 

person in accordance with all applicable codes and standards, 
including fire-rated construction.

18.  Sufficient air is needed for proper combustion and exhausting  

of gasses through the chimney (flu) of fuel burning equipment  
to prevent back drafting. Follow the heating equipment manufacturers 
guideline and safety standards such as those published by the NFPA 
(National Fire Protection Association) and ASHRAE (American 
Society for Heating Refrigeration and Air Conditioning Engineers)  
and the local building code authorities.

19.  Do not install in a ceiling with insulation greater than R40.
20.  Be careful not to damage existing wiring when cutting or driling into 

walls or ceilings. When cutting the ceiling, do not damage electrical 
wiring and other hidden utilities.

21.  Switch power off at service panel and lock the service disconnecting 

means to prevent power from being switched on accidentally. When 
the service disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel.

22.  If this unit is to be installed over a tub or shower, it must be marked 

as appropriate for the application. When the fan is going to install in 
the bathroom, the fan and the tub need to be more than 3' (1 m) 
between each other, the fan required to install at the other side of the 
tub in ceiling. Acceptable for use over a bathtub or shower when 
installed in a GFCI protected branch circuit.

23.  DO NOT use rigid conduit for the installation.
24.  Duct work should be installed in a straight line with minimal bends.
25.  Duct work size must be the same size as the discharge and should 

not be reduced. Reducing the duct size may increase fan noise.

26.  For CUL only: Mount with the lowest moving parts at least  

8’ 2" (2.5 m) above floor or grade level.

Summary of Contents for 3291019

Page 1: ...26 Ventilateur de salle de bains 50 ou 70 PCM IMPORTANT Veuillez lire les instructions qui suivent et conserver ce guide AVIS l installateur remettez ce guide au propri taire Au propri taire conservez...

Page 2: ...instructions des blessures ou des dommages mat riels pourraient survenir Veuillez conserver ce guide pour le consulter ult rieurement Retirez d licatement le produit de l emballage Consultez la liste...

Page 3: ...le moteur ou la bo te de d rivation 6 Veuillez prot ger les cordons lectriques contre les bords tranchants l huile la graisse les surfaces chaudes les produits chimiques ou d autres objets 7 N assembl...

Page 4: ...ecter les directives du fabricant de l quipement de chauffage et les normes de s curit publi es par l Association nationale de proctection contre les incendies NFPA et la Soci t Am ricaine pour les In...

Page 5: ...d terminer en toute s curit MISE EN GARDE Un c blage incorrect de ce produit pourrait entra ner des chocs lectriques un risque d incendie ou un endommagement du produit Consultez un lectricien accr d...

Page 6: ...s ou supprim s 5 aux dommages purement esth tiques et n affectant pas l usage normal du Produit 6 lorsque les dommages d fectuosit s d fauts ou autres probl mes sont caus s par a un entretien inad qu...

Page 7: ...ation Guide 3291019 3291026 Bathroom Fan 50 70 CFM IMPORTANT Please read and keep this guide NOTICE To the installer you must leave this guide with the owner To the owner keep this guide for future re...

Page 8: ...ions contained herein could result in personal injury or property damage We recommend that you keep this guide for future reference Unpack and carefully remove unit from carton Refer to the list of pa...

Page 9: ...and Health Act 5 Always disconnect the power supply prior to servicing the fan motor or junction box 6 Protect the electrical wires from sharp edges oil grease hot surfaces chemicals or other objects...

Page 10: ...nd safety standards such as those published by the NFPA National Fire Protection Association and ASHRAE American Society for Heating Refrigeration and Air Conditioning Engineers and the local building...

Page 11: ...e this safely WARNING Failure to wire product correctly could result in electrical shock fire hazards or damage to the product Consult a licensed electrician if you are unsure of your ability to corre...

Page 12: ......

Reviews: