Page 7
5. Id plate and marking data
All actuators have
marking and are destined for use in the European
Union without further requirements.
The
marking on the product, packaging and indications for use
provided with the product indicate ‘presumed conformity to the
directives’ issued by the European Community.
The manufacturer holds the technical archive with documentation
providing that products have been examined and evaluated for
conformity to directives.
ID plate data are indicated on a polyethylene adhesive label applied
externally on the outside of the container, printed in black on a grey
background. Values conform to EC requirements in force.
See figure for example of labelling.
6. Construction and standards
The SKY 450 rack actuator has been designed and manufactured to open and
close top hung windows opening outwards, bottom hung windows, dormer
windows, light domes, skylights and louvered windows or sun blades. Specific
use is for ventilation and airing of areas; any other use must previously be
approved by the manufacturer.
Application is performed using the brackets provided and any other type of
assembly should be checked with the manufacturer, who will not accept any
responsibility for incorrect or malfunctioning assembly.
Electrical connections must comply with standards in force on the design and
production of electrical appliances.
The actuator has been manufactured according to European Union directives
and conforms to
marking.
Any eventual service or control device for the actuator must be produced according to
standards in force and must comply with the standards issued by the European
Community.
The actuator comes packaged in a cardboard container which contains two pieces.
Each package contains:
•
Nr. 2 110÷230V~(a.c.) 50/60Hz electrical actuators
•
Nr. 2 Standard support brackets with respective grips and fixing screws.
(Grips and fixing screws are inside small part packaging).
•
Nr. 2 Brackets for fixing to the frame.
•
Nr. 2 Small part packaging.
•
Nr. 1 Instruction manual.
Page 8
7. Electrical power supply
SKY450 is commercially available in one single version:
SKY450 230VAC: runs on grid tension of 110/230V~ (a.c.), 50/60Hz, with a
three wire cable (L
IGHT
B
LUE
, common neutral; B
LACK
, phase open; B
ROWN
,
phase closed).
8. Instructions for assembly
These indications are for specialised technical personnel and basic work and
safety techniques are not indicated.
All preparatory, assembly and electrical connection operations must be performed by
specialised technical personnel to guarantee optimal function and service of the
actuator.
Check that the following fundamental conditions have been met:
Actuator specifications must be sufficient for movement of the window
without encountering any obstacle. The limits indicated in the technical data
table must not be superseded (page 6) and the most appropriate actuator
should be selected. Calculations should be checked using the formula
indicated on page 5.
Attention. Check that the electrical power supply corresponds to that
indicated on the
TECHNICAL DATA
label on the machine.
Ensure that the actuator has not been damaged during transport, first
visually and then by powering in both directions.
For bottom hung window frames injury could be caused by accidental falls of
the window. An appropriately sized flexible link arm or fall prevention safety
system designed to resist a force equal to at least three times the total
weight of the window MUST be installed.
8.1. Preparation of actuator for assembly
Before starting assembly of the actuator, prepare the following material for
completion, equipments and tools.
For fixing onto metal window frames: M5 threaded inserts (6 pieces), M5x12 flat
headed metric screws (6 pieces).
For fixing onto wooden window frames: self threading screws for wood Ø4.5 (6
pieces).
For fixing onto PVC window frames: self threading screws for metal Ø4.8 (6 pieces).
Equipment and tools: measuring tape, pencil, drill/screwdriver, set of drill heads
for metal, insert for screwing in, electricians pliers, screwdrivers.