Page   7 

5.  Id plate and marking data 

All actuators have 

 marking and are destined for use in the European 

Union without further requirements. 

The 

  marking  on  the  product,  packaging  and  indications  for  use 

provided  with  the  product  indicate  ‘presumed  conformity  to  the 
directives’ issued by the European Community. 

The  manufacturer  holds  the  technical  archive  with  documentation 
providing  that  products  have  been  examined  and  evaluated  for 
conformity to directives.  

ID  plate  data  are  indicated  on  a  polyethylene  adhesive  label  applied 
externally  on  the  outside  of  the  container,  printed  in  black  on  a  grey 
background. Values conform to EC requirements in force.  

See figure for example of labelling.  

6.  Construction and standards 

  The SKY 450 rack actuator has been designed and manufactured to open and 

close  top  hung  windows  opening  outwards,  bottom  hung  windows,  dormer 
windows,  light  domes,  skylights  and  louvered  windows  or  sun  blades.  Specific 
use  is  for  ventilation  and  airing  of  areas;  any  other  use  must  previously  be 
approved by the manufacturer.    

  Application  is  performed  using  the  brackets  provided  and  any  other  type  of 

assembly  should  be  checked  with  the  manufacturer,  who  will  not  accept  any 
responsibility for incorrect or malfunctioning assembly. 

  Electrical  connections  must  comply  with  standards  in  force  on  the  design  and 

production of electrical appliances.  

  The  actuator  has  been  manufactured  according  to  European  Union  directives 

and conforms to 

 marking. 

  Any eventual service or control device for the actuator must be produced according to 

standards  in  force  and  must  comply  with  the  standards  issued  by  the  European 
Community.  

The  actuator  comes  packaged  in  a  cardboard  container  which  contains  two  pieces. 
Each package contains: 

  Nr. 2  110÷230V~(a.c.) 50/60Hz electrical actuators 

  Nr. 2  Standard support brackets with respective grips and fixing screws. 

 

(Grips and fixing screws are inside small part packaging). 

  Nr. 2  Brackets for fixing to the frame. 

  Nr. 2  Small part packaging. 

 

Nr. 1  Instruction manual.

 

Page 8 

7.  Electrical power supply 

SKY450 is commercially available in one single version: 

  SKY450  230VAC:  runs  on  grid  tension  of  110/230V~  (a.c.),  50/60Hz,  with  a 

three  wire  cable  (L

IGHT 

B

LUE

,  common  neutral;  B

LACK

,  phase  open;  B

ROWN

phase closed). 

8.  Instructions for assembly 

These indications are for specialised technical personnel and basic work and 

safety techniques are not indicated. 

All  preparatory,  assembly  and  electrical  connection  operations must  be  performed  by 
specialised  technical  personnel  to  guarantee  optimal  function  and  service  of  the 
actuator.  

Check that the following fundamental conditions have been met: 

 

Actuator  specifications  must  be  sufficient  for  movement  of  the  window 
without encountering any obstacle. The limits indicated in the technical data 
table  must  not  be  superseded  (page  6)  and  the  most  appropriate  actuator 
should  be  selected.  Calculations  should  be  checked  using  the  formula 
indicated on page 5. 

 

Attention.  Check  that  the  electrical  power  supply  corresponds  to  that 
indicated on the 

TECHNICAL DATA

 label on the machine. 

 

Ensure  that  the  actuator  has  not  been  damaged  during  transport,  first 
visually and then by powering in both directions. 

 

For bottom hung window frames injury could be caused by accidental falls of 
the window. An appropriately sized flexible link arm or fall prevention safety 
system  designed  to  resist  a  force  equal  to  at  least  three  times  the  total 
weight of the window MUST be installed. 

8.1.  Preparation of actuator for assembly 

Before  starting  assembly  of  the  actuator,  prepare  the  following  material  for 
completion, equipments and tools.  

 

For fixing onto metal window frames: M5 threaded inserts (6 pieces), M5x12 flat 
headed metric screws (6 pieces)

 

For  fixing  onto  wooden  window  frames:  self  threading  screws  for  wood  Ø4.5  (6 
pieces)

 

For fixing onto PVC window frames: self threading screws for metal Ø4.8 (6 pieces)

 

Equipment and tools: measuring tape, pencil, drill/screwdriver, set of drill heads 
for metal, insert for screwing in, electricians pliers, screwdrivers. 

Summary of Contents for SKY 450

Page 1: ...throughout the European Union without any further formality The marking on the product packaging and indications for use provided with the product indicate presumed conformity to the directives issue...

Page 2: ...l review of the assembly The following safety indications should be observed carefully The appliance must be installed by competent and qualified technical personnel After removing packaging check for...

Page 3: ...safety reasons always check application before fixing the actuator to the frame or sash In the event of difficulty request assistance from the manufacturer to check application 3 Technical informatio...

Page 4: ...rt packaging Nr 2 Brackets for fixing to the frame Nr 2 Small part packaging Nr 1 Instruction manual Page 8 7 Electrical power supply SKY450 is commercially available in one single version SKY450 230V...

Page 5: ...ing windows Page 10 8 4 Assembly with bottom hung windows A Pencil in the centre line for the window on both mobile and fixed parts Fig 1 B Position the motor support bracket at the edge of the frame...

Page 6: ...able B Position and assemble the support frames for the actuator see detailed explanation in the paragraph entitled assembly for top hung windows opening outwards Page 12 C Position the brackets onto...

Page 7: ...one hand and use the other hand to remove the pin screw This operation should be performed with the window open at least 10 cm to make it easier to remove the screw 3 Manually open the window ATTENTIO...

Page 8: ...legislative che traspongono le seguenti direttive Direttiva 2004 108 CE Direttiva EMC e successivi emendamenti Direttiva 2006 95 CE Direttiva Bassa Tensione e successivi emendamenti Is in accordance...

Reviews: