12. TROUBLESHOOTING
Problem
Action
The pulse indicator light is
flashing, but the electric
shock delivered by the
fence is weak.
Check that all connections in the fence and ground system are
firm and secure. If necessary, clean away any corrosion.
Check that the ground rod is pushed firmly into firm ground.
Check for faults in the fence-line caused by trees or
vegetation. If necessary, remove obstructions and mend the
fence.
Check that the unit (charger) rating is adequate for the length of
the fence. If necessary, reduce the length of the fence or reduce
the number of fence wires. Alternatively, divide the fence-line
into smaller zones, with each zone powered by a separate unit.
The pulse indicator light is
not flashing.
Check that the unit is switched on.
If there has been insufficient sunlight to charge the battery, the
unit may be in Standby mode. Charge the battery by placing the
unit in full sunlight with the solar panel facing true south in the
northern hemisphere and true north in the southern
hemisphere.
Ensure the battery is connected correctly with the positive (red)
lead to the positive (+) terminal on the battery and the negative
(black) lead to the negative (–) terminal on the battery.
Try charging the battery manually using a suitable battery
charger.
Replace the battery with a new battery. Before installing a new
battery, charge it fully using a suitable battery charger.(See
Battery charging chapter)
If the pulse indicator light is still not flashing, please contact the
seller.
The battery needs
Frequent replacement.
Check that the solar panel is clean and is not damaged. (See
Maintenance chapter)
Make sure the unit is positioned to receive maximum sunlight. If
necessary, remove any objects or vegetation that might be
casting a shadow on the unit. (See Positioning the unit chapter),
or for more detailed information on solar installations.
After the unit is switched
on, the pulse indicator
light gives three long
flashes (2 seconds) then
the unit appears to be off.
The unit is in Standby mode because there has been
insufficient sunlight to charge the battery. Charge the
battery by placing the unit in full sunlight with the solar
panel facing true south in the northern hemisphere and true
north in the southern hemisphere.
The pulse indicator light
flashes
quickly
several
times and then there is a
pause.
There may be a problem with the unit. Return the unit to the
seller.