4.3 Changing nosepieces
The nosepieces A) are marked with numbers corresponding to the rivet size. Hold
the power switch(E) pressed, that will lead to the clamping mechanism moving
into the rear position. Use the wrench to change the nosepiece (A) and release
the power switch.
4.4 Riveting
Insert the rivet into the nosepiece (A) and the other end of the rivet into the
work-pieces to be riveted. Press the power switch until the rivet is removed, then
release the power switch. Tilt the riveting device backwards so that the removed
mandrel pin falls into the mandrel
collector (D). If the rivet doesn’t come off in a
single working stroke, repeat the procedure.
4.5 Failure
Over Current Protection: If the battery is over- loaded, the device will stop
operating and the failure indication (C) will light up in red for 5 seconds. In this
case, don’t press the trigger (E) anymore, please unfix the front sleeve (B), then
press the trigger (E) to reset the device to normal state.
Low Voltage Protection: If the battery is empty or with low voltage, the device is
powered down by a protective circuit and the failure indication (C) will light up in
yellow for 10 seconds.
Warning: Rivet size must be suitable for nosepiece (A), for example, 5mm
nosepiece should be fixed with 5mm rivet.
Warning: During the riveting work, user must use the corresponding
rivets, or will make the tool damage.