background image

TROUBLESHOOTING 

 

Problem 

Possible causes 

Possible solutions 

Pump runs, 

but 

will not deliver 

any water. 

1. Screen and/or impeller 

clogged. 

2. When starting, the pump water 

height (1/8") falls below the 

minimum water level. 

3. Low line voltage. 

1. Remove screen. Clean out dirt and 

debris from screen and impeller, then 

replace. 

2. There must be at least 1/8" deep 

water for the Pump to operate 

properly. 

3. Replace 12VDC battery. 

Pump won't 

start 

or run. 

1. Check power connections and 

circuits/fuses. 

2. Water level too low. 

3. Impeller clogged. 

4. Defective motor. 

1. Consult with an electrician. 

2. Allow water level to rise above 1/8

”. 

3. Remove screen. Clean out dirt and 

debris from screen and impeller, then 

replace. 

4. Replace Bilge Pump. 

Excessive 

noise or 

vibration. 

1. Worn bearings. 

2. Debris in impeller. 

1. Replace bilge pump. 

2. Remove screen. Clean impeller. 

Replace screen. 

Pump stops 

often. 

1. Water temperature too high. 

1. Do not exceed temperatures above 

77° F. 

 

TECHNICAL DATA 
 

Model 

CT1731 

CT1732 

CT1733 

Open Flow Rating 

1000 GPH 

2000 GPH 

2000 GPH 

Power Source 

12 Volts   

12 Volts 

12 Volts 

Current 

5.5 Amps   

11 Amps   

13 Amps   

Max. Fuse 

7 Amps     

15 Amps   

18 Amps   

Outlet Diameter 

28.5 mm 

28.5 mm 

32 mm 

 

 

 

 

Reviews: