and gloves away from moving parts. Loose clothes, jewelry, or long hair increases the risk of 
injury to persons as a result of being caught in moving parts. 

z

  Avoid unintentional starting. Be sure the switch is off before connecting to the air supply. Do 

not carry the tool with your finger on the switch or connect the tool to the air supply with the 
switch on. 

z

  Remove adjusting keys and wrenches before turning the tool on. A wrench or key that is left 

attached to a rotating part of the tool increases the risk of personal injury. 

z

  Do not overreach. Keep proper footing and balance at all times. Proper footing and balance 

enables better control of the tool in unexpected situations. 

z

  Use safety equipment. A dust mask, non-skid safety shoes and a hard hat must be used for 

the applicable conditions. 

z

  Always wear eye protection. Wear ANSI-approved safety goggles. 

z

  Always wear hearing protection when using the tool. Prolonged exposure to high intensity 

noise may result in hearing loss. 

z

  Risk of electric shock. This tool is not provided with an insulated gripping surface. 

Contact with a live wire will also make exposed metal parts of the tool live and shock 
the operator. 

z

  Avoid body contact with grounded surfaces such as pipes, radiators, ranges, and 

refrigerators. There is an increased risk of electric shock. 

z

  Examine the work piece to avoid contact with hidden wiring. Thoroughly investigate the 

work piece for possible hidden wiring before performing work. Contact with live wiring will 
shock the operator. 

z

  Use clamps or another practical way to secure and support the work piece to a stable 

platform. Holding the work by hand or against the body is unstable and may lead to loss 
of control. 
 

z

  Do not force the tool. Use the correct tool for the job. The correct tool will do the job 

better and safer at the rate for which the tool is designed. 

z

  Do not use the tool if the switch does not operate. Any tool that cannot be controlled with 

the switch is dangerous and must be repaired. 

z

  Disconnect the tool from the air source before making any adjustments, changing 

accessories, or storing the tool. Such preventive safety measures reduce the risk of 
starting the tool unintentionally. Turn off and detach the air supply, safely discharge any 
residual air pressure, and release the trigger before leaving the work area. 

z

  Store the tool out of the reach of children and other untrained persons. This tool is 

dangerous in the hands of untrained users. 

z

  Maintain the tool with care. Keep a cutting tool sharp and clean. A properly maintained 

tool, with sharp cutting edges reduces the risk of binding and is easier to control. 

z

  Check for misalignment or binding of moving parts, and any other condition that affects the 

tool s operation. If damaged, have the tool serviced before using. Many accidents are 
caused by poorly maintained tools. There is a risk of bursting if the tool is damaged. 

z

  Use only accessories that are identified by the manufacturer for the specific tool s 

model. Use of an accessory not intended for use with the specific tool model, increases 
the risk of injury to persons. 

z

  Tool service must be performed only by qualified repair personnel. 

Summary of Contents for CT0676

Page 1: ...HAMMER CT0676 ORIGINAL INSTRUCTIONS SAVE THESE INSTRUCTIONS AND PRECAUTIONS READ ALL PRECAUTONS AND INSTRUCTIONS BEFORE USE Cannon Tools Limited Address 20 Station Road Rowley Regis West Midlands B65...

Page 2: ...on its design and type as brought into circulation by us In case of alteration of the machine not agreed upon by us this declaration will lose its validity Product description 150MM AIR HAMMER Model C...

Page 3: ...the presence of flammable liquids gases or dust The tool is able to create sparks resulting in the ignition of the dust or fumes z Keep bystanders children and visitors away while operating the tool D...

Page 4: ...ive wiring will shock the operator z Use clamps or another practical way to secure and support the work piece to a stable platform Holding the work by hand or against the body is unstable and may lead...

Page 5: ...ssory may detach or break during operation z Obey the manual for the air compressor used to power this tool z Install an in line shutoff valve to allow immediate control over the air supply in an emer...

Page 6: ...he shut off valve should be a ball valve because it can be closed quickly Note if an automatic oiler system is not used add a few drops of pneumatic tool oil to the airline connection before operation...

Page 7: ...pply However it is a good safety measure to attempt to discharge the tool in a safe fashion after disconnecting to ensure that the tool is disconnected and not powered WARNING Read the ENTIRE importan...

Page 8: ...rea that is cle prevent distrac along a safe r se to possible ugh extra leng rk piece using hazardous obj hile working TRUCTIONS r is not used use Add a few ent oil 8 ry from accide al air pressure an...

Page 9: ...in this manual must be performed only by a qualified technician To prevent serious injury from accidental operation turn off the tool detach the air supply safely discharge any residual air pressure i...

Page 10: ...g Make sure housing is properly assembled and tight Mechanism contaminated Have qualified technician clean and lubricate mechanism Install in line filter in air supply as stated in this manual Housing...

Page 11: ...11 ASSEMBLY DIAGRAM AND PARTS LIST...

Page 12: ...12 CANNON TOOLS LTD Add 20 station road Rowley Regis west midlands B65 0JU U K Made in China...