Incorrect repairs are dangerous.

Repairs to the appliance should only be
carried out by trained specialist staff.

Only use genuine spare parts when repair-
ing the appliance.

If the power cord of this appliance is dam-
aged, it must be replaced by the manufac-
turer, the manufacturer's Customer Service
or a similarly qualified person in order to
prevent any risk.

Incorrect installation is dangerous.

Connect and operate the appliance only in
accordance with the specifications on the
rating plate.

Connect the appliance to a power supply
with alternating current only via a properly
installed socket with earthing.

The protective conductor system of the do-
mestic electrical installation must be prop-
erly installed.

Never equip the appliance with an external
switching device, e.g. a timer or remote
control.

When the appliance is installed, the mains
plug of the power cord must be freely ac-
cessible. If free access is not possible, an
all-pole isolating switch must be installed in
the permanent electrical installation accord-
ing to the conditions of Overvoltage Cat-
egory III and according to the installation
regulations.

When installing the appliance, check that
the power cable is not trapped or dam-
aged.

12.4 General information

Follow these general instructions during the installation.

¡

For the installation, observe the currently valid build-
ing regulations and the regulations of the local elec-
tricity and gas suppliers.

¡

When discharging the exhaust air, the official and
legal regulations, such as the regional building
code., must be observed.

¡

In order to freely access the appliance for servicing,
select an easy-to-reach installation site.

¡

The surfaces of the appliance are sensitive. Avoid
damaging them during installation.

12.5 Instructions for the electrical
connection

In order to safely connect the appliance to the elec-
trical system, follow these instructions.

WARNING ‒ Risk of electric shock!

It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed.

The mains plug for the mains power cable must be
easily accessible after the appliance is installed.

If this is not possible, an all-pole isolating switch
must be integrated into the permanent electrical in-
stallation according to the conditions of overvoltage
category III and according to the installation regula-
tions.

The permanent electrical installation must only be
wired by a professional electrician. We recommend
installing a residual-current circuit breaker (RCCB)
in the appliance's power supply circuit.

Sharp-edged components inside the appliance may
damage the connecting cable.

Do not kink or trap the connecting cable.

¡

The connection data can be found on the rating
plate. → 

Page 10

¡

The connecting cable is approx. 1.30 m long.

¡

This appliance complies with the EC interference
suppression regulations.

¡

The appliance corresponds to protection class 1.
You should therefore only use the appliance with a
protective earth connection.

¡

Do not connect the appliance to the power supply
during installation.

¡

Ensure that the protection against contact is guaran-
teed during installation.

12.6 Information on the installation situation

¡

Install this appliance on the kitchen ceiling or a
stable suspended ceiling.

¡

To install additional special accessory parts, ob-
serve the enclosed installation instructions.

¡

The width of the extractor hood must correspond at
least with the width of the hob.

¡

To optimally detect the cooking vapours, install the
appliance in the middle of the hob.

12.7 Instructions for the exhaust air pipe

The appliance manufacturer does not provide any war-
ranty for faults attributable to the pipeline.

¡

Use a short, straight exhaust air pipe with as large a
pipe diameter as possible.

¡

Long, rough exhaust air pipes, many pipe bends or
small pipe diameters reduce the suction power and
increase the fan noise.

¡

Use an exhaust pipe that is made of non-combust-
ible material.

¡

To prevent condensate from returning, fit the ex-
haust pipe with a 1° gradient from the appliance.

Summary of Contents for I96BMP5N0

Page 1: ...Extractor hood en User manual and installation instructions 2 I96BMP5N0 I96BMP5N0B I95B CP2N0...

Page 2: ...x 2000 m above sea level Do not use the appliance With an external timer 1 3 Restriction on user group This appliance may be used by children aged 8 or over and by people who have reduced physical sen...

Page 3: ...ted operation is possible if the ap pliance is operated exclusively in circulat ing air mode WARNING Risk of fire Fatty deposits in the grease filters may catch fire Never operate the appliance withou...

Page 4: ...the fuse in the fuse box Do not use steam or high pressure clean ers to clean the appliance WARNING Risk of explosion Highly caustic alkaline or highly acidic clean ing agents in conjunction with alum...

Page 5: ...tching off additional functions reduces power consumption 4 Operating modes You can use your appliance in air extraction mode or circulating air mode 4 1 Air extraction mode The air which is drawn in...

Page 6: ...ive mode If particularly strong odours or vapours develop you can use intensive mode 1 To switch on intensive mode 2 press a appears on the display 2 To switch on intensive mode 1 press again a appear...

Page 7: ...appliance working efficiently for a long time it is important to clean and maintain it carefully 7 1 Cleaning products You can obtain suitable cleaning products from after sales service or the online...

Page 8: ...se filters regularly Requirement The grease filters have been removed 1 Observe the information regarding the cleaning agents 2 Soak the grease filter in hot soapy water Use special grease solvent for...

Page 9: ...k 8 1 Malfunctions Fault Cause and troubleshooting The appliance is not working The mains plug of the power cord is not plugged in Connect the appliance to the power supply The circuit breaker in the...

Page 10: ...oduction number FD You can find the product number E Nr and the pro duction number FD on the appliance s rating plate Depending on the model the rating plate can be found Inside the appliance remove g...

Page 11: ...supply of air the air pressure falls below atmospheric pressure Toxic gases from the flue or the extraction shaft are sucked back into the living space Always ensure adequate fresh air in the room if...

Page 12: ...appliance and wall or high sided unit must be at least 50 mm Grease deposits in the grease filter may catch fire Never work with naked flames close to the appliance e g flamb ing Do not install the a...

Page 13: ...e possible to disconnect the appliance from the electricity supply The appliance must only be connected to a protective contact socket that has been correctly installed The mains plug for the mains po...

Page 14: ...n be adjus ted in 20 mm increments Before installation specify the total height of the support frame and mark the screw holes 2 On the ceiling mark the centre point of the appli ance 3 Use the enclose...

Page 15: ...con nector 3 Seal the joints Installing the flue duct WARNING Risk of injury Components inside the appliance may have sharp edges Wear protective gloves WARNING Risk of electric shock Sharp edged com...

Page 16: ...Stra e 34 81739 M nchen GERMANY 9001665649 9001665649 020218 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolverton Milton K...

Reviews: