en
Installation instructions
20
4.
Connect the appliance-side cable for the lighting.
5.
Swing the filter cover up and ensure that it engages.
6.
Connect the appliance to the power supply.
Removing the appliance
WARNING ‒ Risk of injury!
¡
Components inside the appliance may have sharp
edges.
▶
Wear protective gloves.
¡
Risk of injury when opening and closing the hinges.
▶
Keep your hands away from the hinges.
¡
The appliance is heavy.
▶
To move the appliance, two people are required.
▶
Use only suitable tools and equipment.
1.
Disconnect the appliance from the power supply.
2.
Press the lock on the filter cover.
To prevent the filter cover from swinging down sud-
denly, hold onto the filter cover firmly with two
hands.
3.
Open the filter cover by pulling it downwards.
4.
Swing down the filter cover.
Open the filter cover fully and without pulling on it.
5.
Remove the appliance-side cable for the lighting.
6.
Undo the screws on the hinges up to approx. 7 mm.
Do not loosen them fully.
7.
Unhook and remove the filter cover.
8.
Remove the grease filters.
To avoid causing damage, do not bend the grease
filters.