background image

Installation instructions and

how to use and look after your

built-in cooker hoods 

D99W6N0

NEFF (UK) Ltd

D99W3N0

Summary of Contents for D99W3N0

Page 1: ...Installation instructions and how to use and look after your built in cooker hoods D99W6N0 NEFF UK Ltd D99W3N0...

Page 2: ......

Page 3: ...conveyed back into the kitchen The grease filter absorbs the grease particles in the kitchen vapours The activated carbon filter binds the odorous substances If no activated carbon filter is installed...

Page 4: ...d is situated over a gas hob operate the hood at maximum setting if three or more gas hotplates are operated simultaneously Safety instructions Do not flamb food directly under the extractor hood Risk...

Page 5: ...long periods Filters and maintenance Grease filters Metal mesh filters are used to trap the grease particles in the cooking vapours The filter mats are made from noncombustible metal Caution As the f...

Page 6: ...may be impaired Important Change the activated carbon filter promptly to pre vent the risk of fire from the accumulation of heat when deep fat frying or roasting These filters are not washable and can...

Page 7: ...ng agent Do not use aggressive acidic or caustic clean ers Do not use abrasive agents Replacing the light bulbs 1 Switch off the extractor hood and pull out the mains plug or switch off the electricit...

Page 8: ...appliance in a protective shipping carton All packaging materials are environ mentally friendly and recyclable Please contribute to a better environment by disposing of packaging materials in an envir...

Page 9: ...be achieved if combustion air can flow through non lockable openings e g in doors win dows and via the airintake exhaust air wall box or by other technical measures such as reciprocal interlocking etc...

Page 10: ...erminal in the plug marked E or with the symbol or coloured green or green and yel low 2 Connect the blue Neutral wire to the terminal in the plug marked N or coloured black 3 Connect the brown Live w...

Page 11: ...t the minimum distance between the hob and the extractor hood is maintained 400 mm for the electric or gas hob 4 Drill 12 mm holes A and 8 mm holes B for the extractor hood Drill 8 mm holes C for the...

Page 12: ...r air outlet using the 2 screws 12d provided Ensure that the activated charcoal filters have been inserted see parag Activated carbon filter in Filters and Maintenance chapter with chimney All the ite...

Page 13: ...ind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using the 4 screws 12c supplied Make sure that the outlet of the extensions pieces is aligned with the chi...

Page 14: ...Notes...

Page 15: ...Z5126X5...

Page 16: ...9000 227 443 Printed in Germany 0507 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399 436003841_02 070824 Printed in Italy...

Reviews: