NEFF D96BMV5N5B User Manual Download Page 17

Installation instructions

 en

17

2.

Screw on the brackets for the appliance until they

are hand-tight.

Do not firmly tighten the screws.

3.

Screw in the threaded pin, leaving it protruding out

of the wall by 5–9 mm.

Installing the appliance

1.

First remove the protective film from the back of the

appliance and, following installation, remove the rest

of the film.

2.

When mounting the appliance, ensure that it en-

gages properly with the mounting supports.

3.

To align the appliance horizontally, turn the mount-

ing brackets.

If required, move the appliance to the right or to the

left.

4.

Firmly tighten the screws for the mounting brackets,

holding the mounting brackets in place.

5.

Firmly tighten the knurled nuts.

Piping

Note: 

If you are using an aluminium pipe, smooth the

connection area beforehand.
We recommend the piping with an exhaust air pipe dia-

meter of 150 mm.

Establishing the exhaust air connection (exhaust air

pipe, 150 mm diameter)

Fit the exhaust air pipe directly to the air-pipe con-

nector and seal the joint.

Establishing the exhaust air connection (exhaust

pipe, 120 mm diameter)

1.

Secure the reducing connector to the air-pipe con-

nector.

2.

Secure the exhaust air pipe to the reducing con-

nector.

3.

Seal the joints.

Installing the flue duct

WARNING ‒ Risk of injury!

Components inside the appliance may have sharp

edges.

Wear protective gloves.

WARNING ‒ Risk of electric shock!

Sharp-edged components inside the appliance may

damage the connecting cable.

Do not kink or trap the connecting cable.

1.

Screw the retaining bracket for the flue duct to the

wall.

2.

To separate the flue ducts, remove the adhesive

tape or the flue duct from the protective packaging.

3.

Remove any protective foil from both flue ducts.

4.

Use the 2 screws to screw the upper flue duct to

the sides of the retaining bracket.

Summary of Contents for D96BMV5N5B

Page 1: ...Extractor hood User manual and installation instructions D96BMV5N5 D96BMV5N5B...

Page 2: ...closed spaces in a domestic environment up to an altitude of max 2000 m above sea level Do not use the appliance With an external timer 1 3 Restriction on user group This appliance may be used by chil...

Page 3: ...ing air mode WARNING Risk of fire Fatty deposits in the grease filters may catch fire Never operate the appliance without a grease filter Clean the grease filters regularly Never work with naked flam...

Page 4: ...highly acidic clean ing agents in conjunction with aluminium parts in the interior of the appliance may cause ex plosions Never use highly caustic alkaline or highly acidic cleaning agents In particul...

Page 5: ...n are re duced Only use the additional functions if required Switching off additional functions reduces power consumption 4 Operating modes You can use your appliance in air extraction mode or circula...

Page 6: ...Your appliance is set to air extraction mode by default Note When using it in circulating air mode you require additional accessories When using it in circulating air mode set the operat ing mode 7 Ba...

Page 7: ...pliance is switched off Note You can set the saturation indicator in the Home Connect app depending on the filter used Clean the saturated grease filters and in doing so ob serve the cleaning instruct...

Page 8: ...logo are trademarks of Apple Inc Google Play and the Google Play logo are trademarks of Google LLC 2 Open the Home Connect app and scan the follow ing QR code 3 Follow the instructions in the Home Con...

Page 9: ...n only connect to the extractor hood via the Home Connect app Other connection routes are no longer supported 10 Cleaning and servicing To keep your appliance working efficiently for a long time it is...

Page 10: ...filters every two months WARNING Risk of fire Fatty deposits in the grease filters may catch fire Clean the grease filters regularly Requirement The grease filters have been removed Removing the grea...

Page 11: ...rvice or a similarly qualified per son in order to prevent any risk 11 1 Malfunctions Fault Cause and troubleshooting The appliance is not working The mains plug of the power cord is not plugged in Co...

Page 12: ...on number FD on the appliance s rating plate Depending on the model the rating plate can be found Inside the appliance remove grease filters for ac cess On top of the appliance Make a note of your app...

Page 13: ...ration of Conformity can be found on line at www neff home com uk among the additional documents on the product page for your appliance 1 Only applies to Great Britain 2 4 GHz band 2400 2483 5 MHz Max...

Page 14: ...ures to you Unrestricted operation is possible if the ap pliance is operated exclusively in circulat ing air mode Risk of poisoning from flue gases being drawn back in If an extractor hood with an ope...

Page 15: ...h alternating current only via a properly installed socket with earthing The protective conductor system of the do mestic electrical installation must be prop erly installed Never equip the appliance...

Page 16: ...pipes many pipe bends or small pipe diameters reduce the suction power and increase the fan noise Use an exhaust pipe that is made of non combust ible material To prevent condensate from returning fit...

Page 17: ...ommend the piping with an exhaust air pipe dia meter of 150 mm Establishing the exhaust air connection exhaust air pipe 150 mm diameter Fit the exhaust air pipe directly to the air pipe con nector and...

Page 18: ...event scratches lay soft towels over the edges of the outer flue duct to protect the surface Place the lower flue duct on the appliance and pull it slightly apart 6 Put the lower flue duct over the up...

Page 19: ......

Page 20: ...er te GmbH Carl Wery Stra e 34 81739 M nchen GERMANY 9001653855 9001653855 030303 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Roa...

Reviews: