background image

Important safety information    

en

17

:

Warning – Risk of death! 

Risk of poisoning from flue gases that are 

drawn back in. The exhaust air must not be 

conveyed into a functioning smoke or exhaust 

gas flue or into a shaft which is used to 

ventilate installation rooms that contain 

heating appliances. If the exhaust air is to be 

conveyed into a non-functioning smoke or 

exhaust gas flue, you must obtain the consent 

of the heating engineer responsible.

:

Warning – Danger of death! 

Risk of poisoning from flue gases that are 

drawn back in.

Always ensure adequate fresh air in the room 

if the appliance is being operated in exhaust 

air mode at the same time as room air-

dependent heat-producing appliance is being 

operated.

Room air-dependent heat-producing 

appliances (e.g. gas, oil, wood or coal-

operated heaters, continuous flow heaters or 

water heaters) obtain combustion air from the 

room in which they are installed and discharge 

the exhaust gases into the open air through an 

exhaust gas system (e.g. a chimney).

In combination with an activated vapour 

extractor hood, room air is extracted from the 

kitchen and neighbouring rooms - a partial 

vacuum is produced if not enough fresh air is 

supplied. Toxic gases from the chimney or the 

extraction shaft are sucked back into the living 

space.

Adequate incoming air must therefore 

always be ensured.

An incoming/exhaust air wall box alone will 

not ensure compliance with the limit.

Safe operation is possible only when the 

partial vacuum in the place where the heat-

producing appliance is installed does not 

exceed 4 Pa (0.04 mbar). This can be 

achieved when the air needed for combustion 

is able to enter through openings that cannot 

be sealed, for example in doors, windows, 

incoming/exhaust air wall boxes or by other 

technical means.

In any case, consult your responsible Master 

Chimney Sweep. He is able to assess the 

house's entire ventilation setup and will 

suggest the suitable ventilation measures to 

you.

Unrestricted operation is possible if the vapour 

extractor hood is operated exclusively in the 

circulating-air mode.

:

Warning – Danger of death! 

Risk of poisoning from flue gases that are 

drawn back in. If installing a ventilation system 

in a room with a heat-producing appliance 

connected to a chimney/flue, the electricity 

supply to the hood must be equipped with a 

suitable safety switch.

:

Warning – Risk of injury! 

Components inside the appliance may have 

sharp edges. Wear protective gloves.

Risk of injury! 

The appliance may fall down if it has not 

been properly fastened in place. All 

fastening components must be fixed firmly 

and securely.

Risk of injury! 

The appliance is heavy. To move the 

appliance, 2 people are required. Use only 

suitable tools and equipment.

Risk of injury! 

Changes to the electrical or mechanical 

assembly are dangerous and may lead to 

malfunctions. Do not make any changes to 

the electrical or mechanical assembly. 

Summary of Contents for D96BMV5N5B

Page 1: ...en Instructions for installation and use EXTRACTOR HOOD...

Page 2: ......

Page 3: ...ts installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during opera...

Page 4: ...dows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest th...

Page 5: ...Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Risk of electric shock Penetrating moisture may result in an electric shock Clean the appliance using a d...

Page 6: ...onmentally friendly manner Operating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventil...

Page 7: ...nction will remain active even after the fan is switched off Touch the Q symbol Switching off Touch the Q symbol AirFresh function Switching on Touch the 3 symbol 3 will be shown on the display panel...

Page 8: ...activated charcoal filter are is saturated the corresponding symbols will flash once the appliance has been switched off Metal grease filter Activated charcoal filter Metal grease filter and activated...

Page 9: ...cting the appliance reset all existing connections to the WiFi or other appliances If your extractor hood is connected directly to the hob it cannot be connected to your WiFi as well and you will not...

Page 10: ...the steps for Manually logging into your home network The extractor hood cannot be switched on during the connection process You can cancel the process at any time by pressing the symbol To connect t...

Page 11: ...is available in your country Note For more information and to check whether the remote diagnostics service is available in your country please visit the Help Support area of the Home Connect website f...

Page 12: ...Aggressive all purpose cleaning products Oven spray Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removing metal grea...

Page 13: ...rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher...

Page 14: ...tal mesh grease filter to gain access You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Ple...

Page 15: ...regenerated Z5270X0 Z5170X1 Easy change filter for CleanAir recirculation mod ule can be regenerated Z50XXP0X0 CleanAir air recirculation module can be inte grated Z51FXI0X5 RegeneratableCleanAirreci...

Page 16: ...that the appliance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond...

Page 17: ...coming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does no...

Page 18: ...flue gases that are drawn back in The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating...

Page 19: ...ck It must always be possible to disconnect the appliance from the electricity supply The appliance must only be connected to a protective contact socket that has been correctly installed The mains pl...

Page 20: ...2 Use the enclosed template to mark the positions for the screws and the outline of the attachment area 3 Drill five 8 mm diameter holes to a depth of 80 mm for fastening the appliance and press in t...

Page 21: ...e air pipe connector and seal Exhaust air pipe 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appr...

Page 22: ...6...

Page 23: ...6...

Page 24: ...9001359245 9001359245 en...

Reviews: