background image

 

en

3

Ú

 Table of contents

[en]Instructions for installation and use

INSTRUCTION MANUAL ..........................................................3

8

Intended use ......................................................... 3

(

Important safety information .............................. 4

7

Environmental protection.................................... 6

Ç

Operating modes.................................................. 6

1

Operating the appliance ...................................... 7

2

Cleaning and maintenance................................ 11

3

Trouble shooting................................................ 12

4

Customer service ............................................... 13

INSTALLATION INSTRUCTIONS...........................................14

(

Important safety information ............................ 14

K

General information ........................................... 17

5

Installation .......................................................... 18

INSTRUCTION MANUAL

Produktinfo

Additional information on products, accessories, 

replacement parts and services can be found at 

www.neff-international.com

 and in the online shop 

www.neff-eshop.com

8

Intended use

Intended use

Read these instructions carefully. Only then 

will you be able to operate your appliance 

safely and correctly. Retain the instruction 

manual and installation instructions for future 

use or for subsequent owners.
The appliance can only be used safely if it is 

correctly installed according to the safety 

instructions. The installer is responsible for 

ensuring that the appliance works perfectly at 

its installation location.
This appliance is intended for domestic use 

and the household environment only. The 

appliance is not intended for use outside. Do 

not leave the appliance unattended during 

operation. The manufacturer is not liable for 

damage which is caused by improper use or 

incorrect operation.

This appliance is intended for use up to a 

maximum height of 2000 metres above sea 

level.
This appliance may be used by children over 

the age of 8 years old and by persons with 

reduced physical, sensory or mental capacity 

or by persons with a lack of experience or 

knowledge if they are supervised by someone 

who is responsible for their safety, or have 

been instructed in how to use the appliance 

safely and have understood the risks involved 

in not using it properly.
Children must not play with the 

appliance.Cleaning and user maintenance 

must not be performed by children unless they 

are over 15 years of age and are supervised.
Keep children below the age of 8 years old at 

a safe distance from the appliance and power 

cable.
Check the appliance for damage after 

unpacking it. Do not connect the appliance if it 

has been damaged in transport.
This appliance is not intended for operation 

with an external clock timer or a remote 

control.

Summary of Contents for D96BMU5N0A

Page 1: ...en Instructions for installation and use EXTRACTOR HOOD...

Page 2: ......

Page 3: ...ion This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer...

Page 4: ...dows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest th...

Page 5: ...Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Risk of electric shock Penetrating moisture may result in an electric shock Clean the appliance using a d...

Page 6: ...onmentally friendly manner Operating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventil...

Page 7: ...e is a large build up of odours and fumes vapours Switching on Touch the symbol will light up on the display Touch the symbol again to switch back to intensive mode Note After approx 6 minutes the ext...

Page 8: ...ust be switched over accordingly The extractor hood must be connected and switched on Touch and hold the Q symbol and touch the or A symbol until 2 lights up for air recirculation mode filters that ca...

Page 9: ...e fan will switch itself off automatically if the automatic air sensor detects no further change in the air quality in the room Automatic mode can run for a maximum of 4 hours Fan run on time Switchin...

Page 10: ...To do this touch the A symbol Switching over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must be c...

Page 11: ...nderneath with your other hand 2 Take the metal grease filter out of the holder Notes Fat may accumulate in the bottom of the metal grease filter Hold the metal grease filter level to prevent fat from...

Page 12: ...e metal grease filter has not been inserted correctly open the lock and reinsert the metal grease filter correctly 3Trouble shooting TroubleshootingMalfunctions often have simple explanations Please r...

Page 13: ...ance models It may be the case that an optional accessory that is listed does not apply for your appliance Note Observe the installation instructions in the accessory E no FD no After sales serviceO G...

Page 14: ...liance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least wi...

Page 15: ...coming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does no...

Page 16: ...egrated into the permanent electrical installation according to the conditions of overvoltage category III and according to the installation regulations The permanent electrical installation must only...

Page 17: ...ting pipe diameters Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure gr...

Page 18: ...2 Use the enclosed template to mark the positions for the screws and the outline of the attachment area 3 Drill five 8 mm diameter holes to a depth of 80 mm for fastening the appliance and press in t...

Page 19: ...e air pipe connector and seal Exhaust air pipe 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appr...

Page 20: ...9001359222 9001359222 980615 en...