background image

Installation instructions

 en

13

Grease deposits in the grease filter may catch
fire.

Never work with naked flames close to the
appliance (e.g. flambéing).

Do not install the appliance near a heat-
producing appliance for solid fuel (e.g.
wood or coal) unless a closed, non-remov-
able cover is available. There must be no
flying sparks.

WARNING ‒ Risk of injury!

Components inside the appliance may have
sharp edges.

Wear protective gloves.

The appliance may fall down if it has not been
properly fastened in place.

All fastening components must be fixed
firmly and securely in place.

The appliance is heavy.

To move the appliance, two people are re-
quired.

Use only suitable tools and equipment.

The appliance is heavy.

The appliance must not be fitted directly
onto plasterboard or similar lightweight ma-
terials.

To ensure correct installation, you must use
a material which is sufficiently stable and
suitable for both the structural conditions
and the weight of the appliance.

Changes to the electrical or mechanical as-
sembly are dangerous and may lead to mal-
functions.

Do not make any changes to the electrical
or mechanical assembly.

WARNING ‒ Risk of electric shock!

Sharp-edged components inside the appli-
ance may damage the connecting cable.

Do not kink or trap the connecting cable.

If the appliance or the power cord is dam-
aged, this is dangerous.

Never operate a damaged appliance.

Never pull on the power cord to unplug the
appliance. Always unplug the appliance at
the mains.

If the appliance or the power cord is dam-
aged, immediately unplug the power cord
or switch off the fuse in the fuse box.

Call customer services. → 

Page 10

Incorrect repairs are dangerous.

Repairs to the appliance should only be
carried out by trained specialist staff.

Only use genuine spare parts when repair-
ing the appliance.

If the power cord of this appliance is dam-
aged, it must be replaced by the manufac-
turer, the manufacturer's Customer Service
or a similarly qualified person in order to
prevent any risk.

Incorrect installation is dangerous.

Connect and operate the appliance only in
accordance with the specifications on the
rating plate.

Connect the appliance to a power supply
with alternating current only via a properly
installed socket with earthing.

The protective conductor system of the do-
mestic electrical installation must be prop-
erly installed.

Never equip the appliance with an external
switching device, e.g. a timer or remote
control.

When the appliance is installed, the mains
plug of the power cord must be freely ac-
cessible. If free access is not possible, an
all-pole isolating switch must be installed in
the permanent electrical installation accord-
ing to the conditions of Overvoltage Cat-
egory III and according to the installation
regulations.

When installing the appliance, check that
the power cable is not trapped or dam-
aged.

12.4 General information

Follow these general instructions during the installation.

¡

For the installation, observe the currently valid build-
ing regulations and the regulations of the local elec-
tricity and gas suppliers.

¡

When discharging the exhaust air, the official and
legal regulations, such as the regional building
code., must be observed.

¡

In order to freely access the appliance for servicing,
select an easy-to-reach installation site.

¡

The surfaces of the appliance are sensitive. Avoid
damaging them during installation.

Summary of Contents for D96BMU5N0

Page 1: ...Extractor hood en User manual and installation instructions 2 D95BMS5N5 D96BMU5N0 D96B MU5N0A...

Page 2: ...ax 2000 m above sea level Do not use the appliance With an external timer 1 3 Restriction on user group This appliance may be used by children aged 8 or over and by people who have reduced physical se...

Page 3: ...ted operation is possible if the ap pliance is operated exclusively in circulat ing air mode WARNING Risk of fire Fatty deposits in the grease filters may catch fire Never operate the appliance withou...

Page 4: ...ic alkaline or highly acidic clean ing agents in conjunction with aluminium parts in the interior of the appliance may cause ex plosions Never use highly caustic alkaline or highly acidic cleaning age...

Page 5: ...de or circulating air mode 4 1 Air extraction mode The air which is drawn in is cleaned by the grease fil ters and conveyed to the exterior by a pipe system The air must not be discharged into a flue...

Page 6: ...You can use the control panel to configure all functions of your appliance and to obtain information about the operat ing status Switching the appliance on or off Switching noise reduction on or off...

Page 7: ...set automatically using a sensor Press 6 13 Switching off automatic mode1 Press a The ventilation is automatically ended when the sensor detects no further change in the room air quality a Automatic m...

Page 8: ...ic shock An ingress of moisture can cause an electric shock Before cleaning pull out the mains plug or switch off the fuse in the fuse box Do not use steam or high pressure cleaners to clean the appli...

Page 9: ...The grease filters have been removed 1 Observe the information regarding the cleaning agents 2 Place the grease filters loosely into the dishwasher Do not clean heavily soiled grease filters with uten...

Page 10: ...trical and electronic equip ment WEEE The guideline determines the frame work for the return and recycling of used appliances as applicable throughout the EU 10 Customer Service If you have any querie...

Page 11: ...ide 345 mm Z51CBI2X4 Accessories Order number Clean Air Standard odour filter narrow 260 mm Z53CXB1X4 Clean Air Standard odour filter wide 345 mm Z53CBB2X4 Clean Air Standard recir culation kit extern...

Page 12: ...ble to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the ap pliance is operated exclusively in circulat in...

Page 13: ...n the fuse box Call customer services Page 10 Incorrect repairs are dangerous Repairs to the appliance should only be carried out by trained specialist staff Only use genuine spare parts when repair i...

Page 14: ...n the appliance and wall or high sided unit must be at least 50 mm The width of the extractor hood must correspond at least with the width of the hob To optimally detect the cooking vapours install th...

Page 15: ...the mounting brackets in place 5 Firmly tighten the knurled nuts Piping Note If you are using an aluminium pipe smooth the connection area beforehand We recommend the piping with an exhaust air pipe...

Page 16: ...from both flue ducts 4 Use the 2 screws to screw the upper flue duct to the sides of the retaining bracket 5 Note To prevent scratches lay soft towels over the edges of the outer flue duct to protect...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...Stra e 34 81739 M nchen GERMANY 9001653715 9001653715 020218 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolverton Milton K...