background image

Imp

ort

Ap

plia

nce

s.c

om

THE EASIEST WAY TO SELF-IMPORT APPLIANCES DIRECT FROM EUROPE.

en

    Important safety information

4

:

Warning

Risk of burns!

The accessible parts become very hot when in 

operation. Never touch hot parts. Keep 

children at a safe distance.

:

Warning

Risk of injury!

Components inside the appliance may have 

sharp edges. Wear protective gloves.

Risk of injury!

Items placed on the appliance may fall 

down. Do not place any objects on the 

appliance.

Risk of injury!

The light emitted by LED lights is very 

dazzling, and can damage the eyes (risk 

group 1). Do not look directly into the 

switched on LED lights for longer than 100 

seconds.

:

Warning

Risk of injury!

Risk of trapping body parts when opening and 

closing the glass front. Do not reach into the 

area behind the glass panel, and keep your 

fingers away from the hinges.

:

Warning

Hazard due to magnetism!

Permanent magnets are inserted in the 

appliance front. They may affect electronic 

implants, e.g. heart pacemakers or insulin 

pumps. Wearers of electronic implants must 

stay at least 10 cm away from the appliance 

front.

:

Warning

Risk of electric shock!

A defective appliance may cause electric 

shock. Never switch on a defective 

appliance. Unplug the appliance from the 

mains or switch off the circuit breaker in the 

fuse box. Contact the after-sales service.

Risk of electric shock!

Incorrect repairs are dangerous. Repairs 

may only be carried out and damaged 

power cables replaced by one of our 

trained after-sales technicians. If the 

appliance is defective, unplug the appliance 

from the mains or switch off the circuit 

breaker in the fuse box. Contact the after-

sales service.

Risk of electric shock!

Do not use any high-pressure cleaners or 

steam cleaners, which can result in an 

electric shock.

Causes of damage
Caution!

Risk of damage due to corrosion. Always 

switch on the appliance while cooking to avoid 

condensation. Condensate can produce 

corrosion damage.
Always replace faulty bulbs to prevent the 

remaining bulbs from overloading.
Risk of damage due to ingress of humidity into 

the electronic circuitry. Never clean operator 

controls with a wet cloth.
Surface damage due to incorrect cleaning. 

Clean stainless steel surfaces in the direction 

of the grain only. Do not use any stainless 

steel cleaners for operator controls.
Surface damage due to strong or abrasive 

cleaning agents. Never use strong and 

abrasive cleaning agents.
Risk of damage from returning condensate. 

Install the exhaust duct in such a way that it 

falls away from the appliance slightly (1° 

slope).
Risk of damage as a result of incorrect 

loading of design elements. Do not pull design 

elements.Do not place objects on the design 

elements or hang objects from them.

Summary of Contents for D95IMW1N0

Page 1: ...M EUROPE Thanks for choosing ImportAppliances for your kitchen appliance purchase We hope you are enjoying the convenience quality and affordability of your new appliance If you have any issues or que...

Page 2: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE en Instructions for installation and use Extractor hood...

Page 3: ...works perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance una...

Page 4: ...cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s ent...

Page 5: ...e circuit breaker in the fuse box Contact the after sales service Risk of electric shock Incorrect repairs are dangerous Repairs may only be carried out and damaged power cables replaced by one of our...

Page 6: ...ironmentally friendly manner Operating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to vent...

Page 7: ...g off Touch the symbol Noise reduction function The noise reduction function reduces the fan noise Switching on Note This function can be used at any fan setting except fan setting The function will r...

Page 8: ...etal grease filter and activated charcoal filter and If you have not yet done so the metal grease filters should now be cleaned or the activated charcoal filter replaced Cleaning and maintenance on pa...

Page 9: ...f automatically Switching off Touch the symbol to select a different fan setting This immediately stops fan run on Intensive setting You can use the intensive setting if there is a large build up of o...

Page 10: ...ng To do this touch the A symbol Switching over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must be...

Page 11: ...ll light up on the display Touch the symbol again to switch back to intensive mode Note After approx 6 minutes the extractor hood automatically switches back to fan setting 3 Switching off If you want...

Page 12: ...onnected and switched on Touch and hold the Q symbol and touch the or A symbol until 2 lights up for air recirculation mode filters that cannot be regenerated Take your finger off the Q symbol This wi...

Page 13: ...off automatically Switching off Touch the symbol to select a different fan setting This immediately stops fan run on Intensive setting You can use the intensive setting if there is a large build up of...

Page 14: ...hing To do this touch the A symbol Switching over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must...

Page 15: ...automatically Switching off Touch the symbol to select a different fan setting This immediately stops fan run on Intensive setting You can use the intensive setting if there is a large build up of odo...

Page 16: ...switched off Metal grease filter Activated charcoal filter Metal grease filter and activated charcoal filter and If you have not yet done so the metal grease filters should now be cleaned or the activ...

Page 17: ...ll purpose cleaning products Oven spray Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removing metal grease filter 1 O...

Page 18: ...Clean the filters with a brush and then rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grea...

Page 19: ...n the rating plate on the top of the appliance You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be req...

Page 20: ...de angled hood with chimney Easy change filter for starter set Z51AIU0X0 Z51AIA0X0 Starter set for air recirculation mode angled hood without chimney Easy change filter for starter set Z51AIT0X0 Z51AI...

Page 21: ...fitted If the extractor hood is to be operated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to...

Page 22: ...liance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least wi...

Page 23: ...peration is possible only when the partial vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is...

Page 24: ...children to play with packaging material KGeneral information GeneralinformationChecking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the s...

Page 25: ...on mode 1 Determine where the extractor hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Not...

Page 26: ...25 Fitting with a flue duct Fitting without a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then...

Page 27: ...r pipe connector and seal the joint Exhaust air pipe dia 120 mm 1 Fit the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Use suitable m...

Page 28: ...n to the sides of the retaining bracket using two screws 7 Clip the lower flue duct section in at the retaining bracket The connection cable must not be damaged Note If an air recirculation optional a...

Page 29: ...com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE www neff international com 9001159981 9001159981 970606 Constructa Neff Vertriebs GmbH Carl Wery Stra e 34 D 81739 M nchen Register you...

Reviews: