Accessories

Order number

Long Life circulated air
set (flat hood)

Z51AFS0X0

Long Life circulated air
set (angled canopy hood)

Z51AIS0X0

Long Life no-flue circu-
lated air set (flat hood)

Z51AFR0X0

Long Life no-flue circu-
lated air set (angled can-
opy hood)

Z51AIR0X0

Long Life odour filter (re-
placement)

Z50XXP0X0

Clean Air Plus circulated
air set (flat hood)

Z51AFI1X6

Clean Air Plus no-flue cir-
culated air set (flat hood)

Z51AFV1X6

Clean Air Plus circulated
air set (angled canopy
hood)

Z51AII1X6

Clean Air Plus no-flue cir-
culated air set (angled
canopy hood)

Z51AIV1X6

Accessories

Order number

Clean Air Plus circulated
air set, external

Z51AXC1N6

Clean Air Plus odour filter
(replacement)

Z51AIB1X6

Clean Air Plus odour filter
(replacement, flat hood)

Z51AFB1X6

Clean Air Plus odour filter
(replacement, angled can-
opy hood)

Z53XXB1X6

13.1 Other accessories

You can purchase other accessories from our after-
sales service, specialist retailers or online.
You will find a comprehensive range of products for
your appliance in our brochures and online:
www.neff-international.com
Accessories vary from one appliance to another. When
purchasing accessories, always quote the exact
product number (E no.) of your appliance.
You can find out which accessories are available for
your appliance in our online shop or from our after-
sales service.

14  Declaration of Conformity

Constructa Neff Vertriebs-GmbH hereby declares that
the appliance with Home Connect functionality con-
forms to the basic requirements and other relevant pro-
visions of Directive 2014/53/EU.
A detailed RED Declaration of Conformity can be found
online at www.neff-international.com among the addi-
tional documents on the product page for your appli-
ance.

Hereby, Constructa Neff Vertriebs-GmbH declares that
the appliance with Home Connect functionality is in
compliance with relevant statutory requirements.
A detailed Declaration of Conformity can be found on-
line at www.neff-home.com/uk among the additional
documents on the product page for your appliance.

2.4 GHz band (2400–2483.5 MHz): Max. 100 mW
5 GHz band (5150–5350 MHz + 5470–5725 MHz):
Max. 100 mW

BE

BG

CZ

DK

DE

EE

IE

EL

ES

FR

HR

IT

CY

LI

LV

LT

LU

HU

MT

NL

AT

PL

PT

RO

SI

SK

FI

SE

NO

CH

TR

IS

UK (NI)

5 GHz WLAN (Wi-Fi): For indoor use only.

AL

BA

MD

ME

MK

RS

UK

UA

5 GHz WLAN (Wi-Fi): For indoor use only.

15  Installation instructions

Observe this information when installing the appliance.

Summary of Contents for D95FRV1S0

Page 1: ...Extractor hood en User manual and installation instructions D95FRV1S0 D95FRW1S0B D95FRW1S0...

Page 2: ...e this appliance For extracting cooking vapour In private households and in enclosed spaces in a domestic environment Up to an altitude of max 2000 m above sea level Do not use the appliance in combin...

Page 3: ...sible if the ap pliance is operated exclusively in circulat ing air mode WARNING Risk of fire Fatty deposits in the grease filters may catch fire Never operate the appliance without a grease filter Cl...

Page 4: ...onjunction with aluminium parts in the interior of the appliance may cause ex plosions Never use highly caustic alkaline or highly acidic cleaning agents In particular do not use commercial or industr...

Page 5: ...nergy Clean or replace the filters at regular intervals The effectiveness of the filter is retained Put the cooking lid on The cooking vapours and condensation are re duced 4 Operating modes You can u...

Page 6: ...ation about the operat ing status Switching the appliance on or off Switching noise reduction on or off Switching the AirFresh function on or off Decreasing the fan setting Increasing the fan setting...

Page 7: ...3 Release to save the setting 6 12 Switching on the lighting The lighting can be switched on and off independently of the ventilation system Note Colour temperature settings are available in the Home...

Page 8: ...upply and is switched on You have a mobile device with a current version of the iOS or Android operating system e g a smart phone The mobile device and the appliance are within range of your home netw...

Page 9: ...ting both appliances to each other via Home Connect and installing these updates as soon as they are provided A Home Connect account which is free of charge is required for this Please note the safety...

Page 10: ...ic using a soft cloth and glass cleaner Clean glass using a soft cloth and glass cleaner 3 Dry with a soft cloth 4 Apply a thin layer of the stainless steel cleaning product to stainless steel surface...

Page 11: ...e cooking va pour Regularly cleaned grease filters guarantee a high level of grease removal WARNING Risk of fire Fatty deposits in the grease filters may catch fire Clean the grease filters regularly...

Page 12: ...for a period of at least 10 years from the date on which your appliance was placed on the market within the European Economic Area Note Under the terms of the manufacturer s warranty the use of Custo...

Page 13: ...ry from one appliance to another When purchasing accessories always quote the exact product number E no of your appliance You can find out which accessories are available for your appliance in our onl...

Page 14: ...es Comply with the safety clearances for the appliance 15 3 Appliance dimensions You will find the dimensions of the appliance here 15 4 Installation recommendation We recommend fitting the appliance...

Page 15: ...ble to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the ap pliance is operated exclusively in circulat in...

Page 16: ...jury when opening and closing the hinges Keep your hands away from the hinges WARNING Risk of electric shock Sharp edged components inside the appli ance may damage the connecting cable Do not kink or...

Page 17: ...Circulating air mode If you are operating the appliance in circulating air mode an optional accessory must be fitted To do this refer to the installation instructions provided For operation in circula...

Page 18: ...n mode If you operate the appliance in air extraction mode a flue cover must be installed Circulating air mode If you are operating the appliance in circulating air mode an optional accessory must be...

Page 19: ...cket 5 Note To prevent scratches lay soft towels over the edges of the outer flue duct to protect the surface Place the lower flue duct on the appliance and pull it slightly apart 6 Put the lower flue...

Page 20: ...Wery Stra e 34 81739 M nchen GERMANY 9001640985 9001640985 010930 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolverton Mil...

Reviews: