background image

en 

Cleaning and servicing

8

6.21 Setting the intermediate position for
the filter cover

On some appliances, the filter cover can be adjusted to
an intermediate position. The intermediate position can
be used to eliminate particularly strong cooking smells
and large amounts of steam.

Take hold of the filter cover in the centre and open it
carefully.

6.22 Resetting the saturation indicator

After cleaning the grease filter or after changing the
odour filter, the saturation indicator can be reset.

Requirements

¡

After the appliance has been switched off, 

 ap-

pears on the display for the grease filter.

¡

After the appliance has been switched off, 

 ap-

pears on the display for the odour filter.

Press  ⁠.

a

The saturation indicator is reset.

6.23 Setting the saturation indicator

The saturation indicator must be adjusted depending
on the filter used.

Requirement:

 The appliance is switched on.

1.

Press and hold  ⁠.

To set circulating-air mode (non-regenerable fil-
ter), press   or   until 

 appears on the dis-

play.

To set circulating-air mode (regenerable filter),
press   or   until 

 and 

 appears on the dis-

play.

To set the air extraction mode, press   or   until

 appears on the display.

2.

Release   to save the setting.

6.24 Switching on the signal tone

Requirement:

 The appliance is switched off.

Press and hold   and   at the same time for ap-
prox. three seconds until a signal sounds.

a

 appears on the display.

6.25 Switching off the signal tone

Requirement:

 The appliance is switched off.

Press and hold   and   at the same time for ap-
prox. three seconds until a signal sounds.

a

 appears on the display.

7  Cleaning and servicing

To keep your appliance working efficiently for a long
time, it is important to clean and maintain it carefully.

7.1 Cleaning products

You can obtain suitable cleaning products from after-
sales service or the online shop.

WARNING ‒ Risk of electric shock!

An ingress of moisture can cause an electric shock.

Before cleaning, pull out the mains plug or switch
off the fuse in the fuse box.

Do not use steam- or high-pressure cleaners to
clean the appliance.

WARNING ‒ Risk of burns!

The appliance becomes hot during operation.

Allow the appliance to cool down before cleaning.

ATTENTION!

Unsuitable cleaning products may damage the sur-
faces of the appliance.

Do not use harsh or abrasive detergents.

Do not use cleaning products with a high alcohol
content.

Do not use hard scouring pads or cleaning
sponges.

Do not use any special cleaners for cleaning the ap-
pliance while it is hot.

Only use glass cleaners, glass scrapers or stainless
steel care products if recommended in the cleaning
instructions for the relevant part.

Wash sponge cloths thoroughly before use.

7.2 Cleaning the appliance

Clean the appliance as specified. This will ensure that
the different parts and surfaces of the appliance are
not damaged by incorrect cleaning or unsuitable clean-
ing products.

WARNING ‒ Risk of explosion!

Highly caustic alkaline or highly acidic cleaning agents
in conjunction with aluminium parts in the interior of the
appliance may cause explosions.

Never use highly caustic alkaline or highly acidic
cleaning agents. In particular, do not use commer-
cial or industrial cleaning agents in conjunction with
aluminium parts, e.g. grease filter on extractor
hoods.

WARNING ‒ Risk of electric shock!

An ingress of moisture can cause an electric shock.

Before cleaning, pull out the mains plug or switch
off the fuse in the fuse box.

Do not use steam- or high-pressure cleaners to
clean the appliance.

WARNING ‒ Risk of burns!

The appliance becomes hot during operation.

Allow the appliance to cool down before cleaning.

WARNING ‒ Risk of injury!

Components inside the appliance may have sharp
edges.

Carefully clean the appliance interior.

Summary of Contents for D95FQQ1N0

Page 1: ...Extractor hood en User manual and installation instructions D95FQQ1N0 D95FQP1N0 D95IPQ1N0 D95IPP1N0 D95IKQ1S0 D95IKP1S0 D95FHQ1S0 D95FHP1S1...

Page 2: ...ly at its installation location Only use this appliance For extracting cooking vapour In private households and in enclosed spaces in a domestic environment Up to an altitude of max 2000 m above sea l...

Page 3: ...ted operation is possible if the ap pliance is operated exclusively in circulat ing air mode WARNING Risk of fire Fatty deposits in the grease filters may catch fire Never operate the appliance withou...

Page 4: ...cord of this appliance is dam aged it must be replaced by trained spe cialist staff An ingress of moisture can cause an electric shock Before cleaning pull out the mains plug or switch off the fuse i...

Page 5: ...nergy Clean or replace the filters at regular intervals The effectiveness of the filter is retained Put the cooking lid on The cooking vapours and condensation are re duced 4 Operating modes You can u...

Page 6: ...g the lighting on or off Setting the brightness 5 2 Controls variant 2 You can use the control panel to configure all functions of your appliance and to obtain information about the operat ing status...

Page 7: ...The NoiseReduction function remains active even after the appliance is switched off 6 12 Switching on automatic mode The optimum fan setting is set automatically using a sensor Press 6 13 Switching of...

Page 8: ...leaning products from after sales service or the online shop WARNING Risk of electric shock An ingress of moisture can cause an electric shock Before cleaning pull out the mains plug or switch off the...

Page 9: ...ers filter the grease from the cooking va pour Regularly cleaned grease filters guarantee a high level of grease removal WARNING Risk of fire Fatty deposits in the grease filters may catch fire Clean...

Page 10: ...old appliance Valuable raw materials can be reused by recycling 1 Unplug the appliance from the mains 2 Cut through the power cord 3 Dispose of the appliance in an environmentally friendly manner Inf...

Page 11: ...0X0 Long Life no flue circu lated air set flat hood Z51AFR0X0 Long Life no flue circu lated air set angled can opy hood Z51AIR0X0 Long Life odour filter re placement Z50XXP0X0 Clean Air Plus circulate...

Page 12: ...es Comply with the safety clearances for the appliance 12 3 Appliance dimensions You will find the dimensions of the appliance here 12 4 Installation recommendation We recommend fitting the appliance...

Page 13: ...ble to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the ap pliance is operated exclusively in circulat in...

Page 14: ...es WARNING Risk of electric shock Sharp edged components inside the appli ance may damage the connecting cable Do not kink or trap the connecting cable If the appliance or the power cord is dam aged t...

Page 15: ...erating the appliance in circulating air mode an optional accessory must be fitted To do this refer to the installation instructions provided For operation in circulating air mode the installation of...

Page 16: ...ppliance to the right or to the left as required 4 Tighten the safety screws When you install a flue cover install the bracket and hold it in place while screwing it in tight Piping Air extraction mod...

Page 17: ...he connecting cable 1 Screw the retaining bracket for the flue duct to the wall 2 To separate the flue ducts remove the adhesive tape or the flue duct from the protective packaging 3 Remove any protec...

Page 18: ......

Page 19: ......

Page 20: ...Wery Stra e 34 81739 M nchen GERMANY 9001641269 9001641269 010930 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolverton Mil...

Reviews: