NEFF D95FMS1N0B/01 Instruction Manual Download Page 2

en

2

Ú

 Table of contents

[en]Instructions for installation and use

INSTRUCTION MANUAL.......................................................... 2

8

Intended use................................................................... 2

(

Important safety information ........................................ 3

7

Environmental protection ............................................. 5

Ç

Operating modes ........................................................... 5

1

Operating the appliance................................................ 6

2

Cleaning and maintenance ......................................... 16

3

Trouble shooting ......................................................... 18

4

Customer service......................................................... 18

INSTALLATION INSTRUCTIONS .......................................... 20

(

Important safety information...................................... 21

K

General information .................................................... 23

5

Installation ................................................................... 24

INSTRUCTION MANUAL

Produktinfo

Additional information on products, accessories, 

replacement parts and services can be found at 

www.neff-international.com

 and in the online shop 

www.neff-eshop.com

8

Intended use

Intended use

Read these instructions carefully. Only then 

will you be able to operate your appliance 

safely and correctly. Retain the instruction 

manual and installation instructions for future 

use or for subsequent owners.
The appliance can only be used safely if it is 

correctly installed according to the safety 

instructions. The installer is responsible for 

ensuring that the appliance works perfectly at 

its installation location.
This appliance is intended for domestic use 

and the household environment only. The 

appliance is not intended for use outside. Do 

not leave the appliance unattended during 

operation. The manufacturer is not liable for 

damage which is caused by improper use or 

incorrect operation.

This appliance is intended for use up to a 

maximum height of 2000 metres above sea 

level.
This appliance may be used by children over 

the age of 8 years old and by persons with 

reduced physical, sensory or mental capacity 

or by persons with a lack of experience or 

knowledge if they are supervised by someone 

who is responsible for their safety, or have 

been instructed in how to use the appliance 

safely and have understood the risks involved 

in not using it properly.
Children must not play with the 

appliance.Cleaning and user maintenance 

must not be performed by children unless they 

are over 15 years of age and are supervised.
Keep children below the age of 8 years old at 

a safe distance from the appliance and power 

cable.
Check the appliance for damage after 

unpacking it. Do not connect the appliance if it 

has been damaged in transport.
This appliance is not intended for operation 

with an external clock timer or a remote 

control.

Summary of Contents for D95FMS1N0B/01

Page 1: ...Dunstabzugshaube de ...

Page 2: ...cation This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance may be used ...

Page 3: ...ndows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Fatty deposits in the g...

Page 4: ...t the after sales service Risk of electric shock Incorrect repairs are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaner...

Page 5: ...modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible If the exhaust air is conveyed throug...

Page 6: ...function The noise reduction function reduces the fan noise Switching on Note This function can be used at any fan setting except fan setting The function will remain active even after the fan is switched off Touch the Q symbol Switching off Touch the Q symbol AirFresh function Switching on Touch the 3 symbol 3 will be shown on the display panel The fan runs for approximately 5 minutes per hour at...

Page 7: ...al filter ª and ª If you have not yet done so the metal grease filters should now be cleaned or the activated charcoal filter replaced Cleaning and maintenance on page 16 The saturation indicators can be reset while they are flashing To do this touch the A symbol Switching over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over accordi...

Page 8: ...symbol to select a different fan setting This immediately stops fan run on Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on Touch the symbol ƒ will light up on the display Touch the symbol again to switch back to intensive mode Note After approx 6 minutes the extractor hood automatically switches back to fan setting 3 Switchi...

Page 9: ...tching over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must be connected and switched off Touch and hold the Q symbol and touch the or A symbol until 2 lights up for air recirculation mode filters that cannot be regenerated Take your finger off the Q symbol This will switch the electronic controll...

Page 10: ...ymbol again to switch back to intensive mode Note After approx 6 minutes the extractor hood automatically switches back to fan setting 3 Switching off If you want to end intensive mode before the preset time expires touch the symbol Intermediate position for the glass front On some appliances the glass front can be adjusted to an intermediate position The intermediate position can be used for elim...

Page 11: ... hold the Q symbol and touch the or A symbol until 2 lights up for air recirculation mode filters that cannot be regenerated Take your finger off the Q symbol This will switch the electronic controller over to air recirculation mode filters that cannot be regenerated Touch and hold the Q symbol and touch the or A symbol until 3 lights up for air recirculation mode filters that can be regenerated T...

Page 12: ...e symbol to select a different fan setting This immediately stops fan run on Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on Touch the symbol ƒ will light up on the display Touch the symbol again to switch back to intensive mode Note After approx 6 minutes the extractor hood automatically switches back to fan setting 3 Switc...

Page 13: ... Switching over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must be connected and switched on Touch and hold the Q symbol and touch the or A symbol until 2 lights up for air recirculation mode filters that cannot be regenerated Take your finger off the Q symbol This will switch the electronic contr...

Page 14: ...mbol to select a different fan setting This immediately stops fan run on Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on Touch the symbol ƒ will light up on the display Touch the symbol again to switch back to intensive mode Note After approx 6 minutes the extractor hood automatically switches back to fan setting 3 Switching...

Page 15: ...d charcoal filter ªª Metal grease filter and activated charcoal filter ªª and ªª If you have not yet done so the metal grease filters should now be cleaned or the activated charcoal filter replaced Cleaning and maintenance on page 16 The saturation indicators can be reset while they are flashing To do this touch the A symbol Switching over the display for air recirculation mode For air recirculati...

Page 16: ...Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removing metal grease filter 1 Open the glass front slowly and fully Hold the glass front in the centre when doing so gripping it firmly 2 Open the lock and swing down the metal grease filter When you do this take hold of the metal grease filter from underneath with your ...

Page 17: ... rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing detergents Do not clean heavily soiled metal grease filters together with cookware Pla...

Page 18: ...liance You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Please be aware that a visit by an after sales engineer will be charged if a problem turns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed customer s...

Page 19: ...filter for starter set Z51AIU0X0 Z51AIA0X0 Starter set for air recirculation mode angled hood without chimney Easy change filter for starter set Z51AIT0X0 Z51AIA0X0 Starter set for air recirculation mode with filter that can be regenerated flat hood with chimney Z51AFS0X0 Starter set for air recirculation mode with filter that can be regenerated angled hood with chim ney Z51AIS0X0 Starter set for ...

Page 20: ...erated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation mode For additional optional accessories refer to the installation instructions provided The surfaces of the appliance are sensitive Avoid damaging them during installation PLQ PP PLQ PP PD PP PLQ PP PLQ PP P...

Page 21: ...on location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers Warning Risk of fire Fatty deposits in the grease filter may catch fire The specifi...

Page 22: ...al vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire...

Page 23: ...l KGeneral information GeneralinformationChecking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structures e g plasterboard porous concrete poroton bricks The max...

Page 24: ...hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor hood such that the lower edge of the glass screen is in line with the lower edges of the adjacent wall hung cabinets Make sure that the specified safety clearances from the hob are complied with 2 Place ...

Page 25: ...hout a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in fully PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP ...

Page 26: ...ust air pipe dia 120 mm 1 Fit the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Use suitable means to seal both joints Attaching the flue duct If the extractor hood is to be operated in exhaust air mode a flue duct must be fitted The flue duct does not need to be fitted for air recirculation mode Warning Risk of injury From sharp ed...

Page 27: ...sing two screws 7 Clip the lower flue duct section in at the retaining bracket The connection cable must not be damaged ª Note If an air recirculation optional accessory has been fitted and the extractor hood is to be operated without a flue duct the cable must be wound onto the connector ...

Page 28: ...Constructa Neff Vertriebs GmbH Carl Wery Straße 34 81739 München GERMANY 9001159981 9001159981 970606 de ...

Reviews: