able to enter through openings that cannot

be sealed, for example in doors, windows,

incoming/exhaust air wall boxes or by

other technical means. An incoming/ex-

haust air wall box alone does not ensure

compliance with the limit.

In any case, consult your responsible chim-

ney sweep. They are able to assess the

house's entire ventilation setup and will

suggest the suitable ventilation measures

to you.

Unrestricted operation is possible if the ap-

pliance is operated exclusively in circulat-

ing-air mode.

Risk of poisoning from flue gases being

drawn back in.

If an extractor hood with an open-flued heat

production source is installed, the power

supply for the extractor hood must be

provided with a suitable safety switch.

Risk of poisoning from flue gases being

drawn back in.

Do not emit the exhaust air into a smoke or

exhaust gas flue that is in operation.

Do not emit the exhaust air into a shaft that

is used to ventilate installation rooms for

heat-producing appliances.

If the exhaust air is to be conveyed into a

smoke or exhaust gas flue, you must obtain

the consent of the heating engineer re-

sponsible.

WARNING ‒ Risk of suffocation!

Children may put packaging material over

their heads or wrap themselves up in it and

suffocate.

Keep packaging material away from chil-

dren.

Do not let children play with packaging ma-

terial.

WARNING ‒ Risk of fire!

Grease deposits in the grease filter may catch

fire.

The specified safety clearances must be

complied with in order to prevent a build-up

of heat.

Observe the specifications for your cooking

appliances. If the installation instructions for

the cooking appliances specify a different

clearance, the larger of the two must al-

ways be provided for. If gas hobs and elec-

tric hobs are operated together, the largest

specified clearance applies.

The appliance must be installed with no

more than one side directly next to a high-

sided unit or a wall. The distance between

the appliance and wall or high-sided unit

must be at least 50 mm.

The grease deposits in the grease filter may

catch fire.

Never work with naked flames close to the

appliance (e.g. flambéing).

Do not install the appliance near a heat-

producing appliance for solid fuel (e.g.

wood or coal) unless a closed, non-remov-

able cover is present. There must be no fly-

ing sparks.

WARNING ‒ Risk of injury!

Components inside the appliance may have

sharp edges.

Wear protective gloves.

The appliance may fall down if it has not been

properly fastened in place.

All fastening components must be fixed

firmly and securely in place.

The appliance is heavy.

To move the appliance, two people are re-

quired.

Use only suitable tools and equipment.

The appliance is heavy.

The appliance must not be fitted directly

onto plasterboard or similar lightweight ma-

terials.

To ensure correct installation, you must use

a material which is sufficiently stable and

suitable for both the structural conditions

and the weight of the appliance.

Changes to the electrical or mechanical as-

sembly are dangerous and may lead to mal-

functions.

Do not make any changes to the electrical

or mechanical assembly.

Summary of Contents for D92PBC0N0B

Page 1: ...Extractor hood User manual and installation instructions D92PBC0N0 D92PBC0N0B D62PBC0N0 D72PBC0N0B D62PBC0N0B...

Page 2: ...esulting dangers Do not let children play with the appliance Children must not perform cleaning or user maintenance unless they are at least 15 years old and are being supervised Keep children under t...

Page 3: ...isk of injury Components inside the appliance may have sharp edges Carefully clean the appliance interior Items placed on the appliance may fall off Do not place any objects on the appliance Changes t...

Page 4: ...design elements or hang objects from them There is a risk of surface damage if you do not peel off the protective film Remove the protective film from all parts of the ap pliance before using for the...

Page 5: ...a non functioning smoke or ex haust gas flue you must obtain the consent of the heating engineer re sponsible If the exhaust air is conveyed through the external wall a tele scopic duct should be used...

Page 6: ...s 8 Cleaning and servicing To keep your appliance working efficiently for a long time it is important to clean and maintain it carefully 8 1 Cleaning the appliance Clean the appliance as specified Thi...

Page 7: ...Cleaning products Page 7 2 Clean using a damp sponge cloth and hot soapy water 3 Dry with a soft cloth 8 4 Removing the grease filter 1 ATTENTION Falling grease filters may damage the hob below Grip b...

Page 8: ...e This will avoid unnecessary costs WARNING Risk of injury Improper repairs are dangerous Repairs to the appliance should only be carried out by trained specialist staff If the appliance is defective...

Page 9: ...le from our after sales service your retailer or on our website If you contact Customer Service you will require the product number E Nr and the production number FD of your appliance The contact deta...

Page 10: ...or water heaters obtain combustion air from the room in which they are installed and dis charge the exhaust gases into the open through an exhaust gas system e g a chim ney With the extractor hood sw...

Page 11: ...fety clearances must be complied with in order to prevent a build up of heat Observe the specifications for your cooking appliances If the installation instructions for the cooking appliances specify...

Page 12: ...ces of the appliance are sensitive Avoid damaging them during installation 13 6 Instructions for the electrical connection In order to safely connect the appliance to the elec trical system follow the...

Page 13: ...r use with solid brickwork Use suitable fixing material for other structures e g plasterboard porous con crete poroton bricks Preparing the wall Note Depending on the design holes must be placed diffe...

Page 14: ...Installing the flue duct WARNING Risk of injury Components inside the appliance may have sharp edges Wear protective gloves 1 Screw the retaining bracket for the flue duct to the wall 2 To separate th...

Page 15: ......

Page 16: ...er te GmbH Carl Wery Stra e 34 81739 M nchen GERMANY 9001673546 9001673546 030317 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Roa...

Reviews: