background image

4

Before using for the first time

Important notes:

The Instructions for Use apply to several
versions of this appliance. Accordingly,
you may find descriptions of individual
features that do not apply to your 
specific appliance.

This extractor hood complies with all 
relevant safety regulations.

Repairs

should be carried out by 

qualified technicians only.

Improper repairs may put the user at
considerable risk.

Do not flambé food directly under the

extractor hood.

Risk of grease filter catching fire due

!

to flames.

The hotplates must always be covered

with a utensil.

Restrictions apply to the use of the

extractor hood over a solid-fuel burner
(coal, wood, etc.). (See Installation 
instructions).

Gas hobs / Gas cookers

Do not use all the gas hotplates 

simultaneously for a prolonged period 
(max. 15 minutes) at maximum thermal
load, otherwise there is a risk of burns if the
housing surfaces are touched or a risk of
damage to the extractor hood. If the 
extractor hood is situated over a gas hob,
operate the hood at maximum setting if
three or more gas hotplates are operated
simultaneously.

Before using your appliance for the first
time, please read these Instructions for
Use carefully. They contain important
information concerning your personal
safety as well as on use and care of the
appliance.

Please retain the operating and 
installation instructions for a subsequent
owner.

Do not use the appliance if damaged.

The appliance is not intended for use

by young children or infirmed persons 
without supervision.
Young children should be supervised to
ensure they do not play with the appliance.

If the connecting cable for this 

appliance is damaged, the cable must be
replaced by the manufacturer or his 
customer service or a similarly qualified 
person in order to prevent serious injury to
the user.

The appliance may be connected to

the mains by a qualified technician only.

Dispose of packaging materials 

properly (see Installation instructions).

This extractor hood is designed for

domestic use only.

Light bulbs must always be fitted when

the extractor hood is in use.

Defective bulbs should be replaced

immediately to prevent the remaining bulbs
from overloading.

Never operate the extractor hood 

without a grease filter.

Overheated fat or oil can easily catch

fire. 
If you are cooking with fat or oil, e.g. chips,
etc., never leave the cooker unattended.

Summary of Contents for D91T7

Page 1: ...Installation instructions and how to use and look after your built in cooker hoods D91T7 NEFF UK Ltd...

Page 2: ...2 Abb 1 ELECTRO Fig 1 GAZ...

Page 3: ...poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the ov...

Page 4: ...aneously Before using your appliance for the first time please read these Instructions for Use carefully They contain important information concerning your personal safety as well as on use and care o...

Page 5: ...g off Repeat the process with the light switched on After approx 3 seconds the light switches off to acknowledge the setting Operating procedure Acoustic signal When a button is pressed this is verifi...

Page 6: ...leaning the metal grease filters In normal operation 1 to 2 hours daily the metal grease filter must be cleaned 1 x a month The filters can be cleaned in a dish washer It is however possible that they...

Page 7: ...filters should be replaced approximately 1 x year A replacement filter can be obtained from any authorized dealer see optional accessories Use original filters only By doing so you will obtain maximum...

Page 8: ...same direction as it has been ground and polished Do not use any of the following to clean stainless steel surfaces abrasive sponges cleaning agents containing sand soda acid or chloride Aluminium and...

Page 9: ...or if a fault occurs please call Customer Service See list of Customer Service representatives When you call please quote the following Setting the saturation indicator If it becomes necessary to cha...

Page 10: ...liance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment...

Page 11: ...air which will be needed by the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be a...

Page 12: ...t of round pipes There should be no sharp bends l 120 mm approx 113 cm2 l 150 mm approx 177 cm2 If pipes have different diameters Insert sealing strip For exhaust air mode ensure that there is an adeq...

Page 13: ...isconnect the extractor hood from the electricity supply Length of the connecting cable 1 30 m If it is necessary to wire the extractor hood directly into the mains The extractor hood should only be c...

Page 14: ...gas hotplates 1 Mark the centre point of the extractor hood on the ceiling 2 Using the template mark screw positions on the ceiling 3 Drill 4x 8 mm holes and insert wall plugs flush with the ceiling 4...

Page 15: ...the support frame at the specified overall height with 8 screws 10 Align the extractor hood To do this loosen the ceiling screws in the support frame 09 Screw the extractor hood to the support frame a...

Page 16: ...ve foil 15 Push up the upper flue section and screw into position 16 Insert the two sections of the lower flue and clip together Protect the extractor hood from damage 14 Place the two sections of the...

Page 17: ...17 Notes...

Page 18: ...18 Notes...

Page 19: ...19 351210 Z5120X5...

Page 20: ...9000 032 337 Printed in Germany 0905 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399...

Reviews: