background image

12

Room air-dependent heat-producing 

appliances (e.g. gas, oil, wood or coal-

operated heaters, continuous flow heaters 

or water heaters) obtain combustion air 

from the room in which they are installed 

and discharge the exhaust gases into the 

open air through an exhaust gas system 

(e.g. a chimney).
In combination with an activated vapour 

extractor hood, room air is extracted from 

the kitchen and neighbouring rooms - a 

partial vacuum is produced if not enough 

fresh air is supplied. Toxic gases from the 

chimney or the extraction shaft are sucked 

back into the living space.

Adequate incoming air must therefore 

always be ensured.

An incoming/exhaust air wall box alone 

will not ensure compliance with the limit.

Safe operation is possible only when the 

partial vacuum in the place where the heat-

producing appliance is installed does not 

exceed 4 Pa (0.04 mbar). This can be 

achieved when the air needed for 

combustion is able to enter through 

openings that cannot be sealed, for 

example in doors, windows, incoming/

exhaust air wall boxes or by other technical 

means.

In any case, consult your responsible 

Master Chimney Sweep. He is able to 

assess the house's entire ventilation setup 

and will suggest the suitable ventilation 

measures to you.
Unrestricted operation is possible if the 

vapour extractor hood is operated 

exclusively in the circulating-air mode.

Danger of death!

Risk of poisoning from flue gases that are 

drawn back in. If installing a ventilation 

system in a room with a heat-producing 

appliance connected to a chimney/flue, the 

electricity supply to the hood must be 

equipped with a suitable safety switch.

Risk of fire!

Grease deposits in the grease filter may 

catch fire. The specified safety distances 

must be observed in order to prevent an 

accumulation of heat. Observe the 

specifications for your cooking appliance. If 

gas and electric hobs are operated 

together, the largest specified distance 

applies.
Only one side of the appliance may be 

installed directly next to a high-sided unit or 

a wall. The distance between the appliance 

and wall or high-sided unit must be at least 

50 mm. 

Risk of injury!

Components inside the appliance may 

have sharp edges. Wear protective gloves.

Risk of injury!

The appliance may fall down if it has not 

been properly fastened in place. All 

fastening components must be fixed firmly 

and securely.

Risk of injury!

The appliance is heavy. To move the 

appliance, 2 people are required. Use only 

suitable tools and equipment.

Risk of electric shock!

Components inside the appliance may have 

sharp edges. These may damage the 

connecting cable. Do not kink or pinch the 

connecting cable during installation.

Risk of electric shock!

It must always be possible to disconnect 

the appliance from the electricity supply. 

The appliance must only be connected to a 

protective contact socket which has been 

correctly installed. If the plug is no longer 

accessible following installation of the 

appliance, or a fixed connection is required, 

an all-pole isolating switch must be present 

on the installation side with a contact gap of 

at least 3 mm. The fixed connection must 

only be installed by an electrician.

Danger of suffocation!

Packaging material is dangerous to 

children. Never allow children to play with 

packaging material.

Summary of Contents for D86EH52N0B/01

Page 1: ... en Instructions for installation and use Extractor hood ...

Page 2: ...ctly Retain the instruction manual and installation instructions for future use or for subsequent owners The appliance can only be used safely if it is correctly installed according to the safety instructions The installer is responsible for ensuring that the appliance works perfectly at its installation location This appliance is intended for domestic use and the household environment only The ap...

Page 3: ...cal means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Risk of fire Grease deposits in the grease filter may catch fire Clean the grease filter at least ev...

Page 4: ...ed after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Penetrating moisture may cause an electric shock Do not use any high pressure cleaners or steam cleaners Causes of damage Caution Risk of damage due to corrosion Always switch on the appliance while coo...

Page 5: ...must install an activated carbon filter The different options for operating the appliance in circulating air mode can be found in the brochure Alternatively ask your dealer The required accessories are available from specialist retailers from customer service or from the Online Shop For appliances with an additional internal filter only the CleanAir recirculation module see Accessories for circula...

Page 6: ...the fan switches off automatically AirFresh function Press the button until 3 appears The fan runs for approx five minutes per hour If you want to end the AirFresh function press the button Lighting The lighting can be switched on and off independently of the fan Press the A button Setting the brightness Press and hold the A button until the desired brightness is reached Saturation display When th...

Page 7: ...s active after the fan is switched off Switching off the appliance Press the 4 button Lighting The lighting can be switched on and off independently of the fan Press the A button Setting the brightness Press and hold the A button until the desired brightness is reached Saturation display When the metal mesh grease filters or the activated carbon filter are saturated a signal sounds for approx 4 se...

Page 8: ...appliance using a damp cloth The metal mesh grease filters can be cleaned in the dishwasher or by hand In the dishwasher Note If the metal mesh grease filters are cleaned in the dishwasher slight discolouration may occur This has no effect on the function of the metal mesh grease filters Do not clean heavily soiled metal mesh grease filters together with utensils Place the metal mesh grease filter...

Page 9: ...e fuse box Contact the after sales service Malfunction table Replacing bulbs Risk of electric shock When changing the bulbs the bulb socket contacts are live Before changing the bulb unplug the appliance from the mains or switch off the circuit breaker in the fuse box Important Only use a bulb of the same type and same power see the bulb holder or rating plate inside the appliance to do this remov...

Page 10: ...est assured that the repair will be carried out by trained service technicians using original spare parts for your domestic appliance Accessories for circulating air mode not included in the delivery Notes Follow the installation instructions supplied with the accessories For appliances with an additional internal filter only the CleanAir recirculation module can be used Basic equipment Starter se...

Page 11: ...orrespond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers When conveying the exhaust air official and legal regulations e g state building regulations must be followed Risk of death Risk of poisoning from flue gases that are drawn back in The exhaust air must not be conveyed into...

Page 12: ...ney flue the electricity supply to the hood must be equipped with a suitable safety switch Risk of fire Grease deposits in the grease filter may catch fire The specified safety distances must be observed in order to prevent an accumulation of heat Observe the specifications for your cooking appliance If gas and electric hobs are operated together the largest specified distance applies Only one sid...

Page 13: ...es must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structures e g plasterboard porous concrete poroton bricks The max weight of the extractor hood is 40 kg Electrical connection Risk of electric shock Components inside the appliance may have sharp edges These m...

Page 14: ...protective foil from the back of the appliance and following installation remove the foil completely 2 When attaching the appliance ensure that it engages firmly with the brackets 3 Align the appliance horizontally by turning the brackets If required the appliance can be moved to the right or left Securing the appliance 1 Press the safety caps with the arrow upwards onto the brackets until they en...

Page 15: ...aching the flue duct Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance 1 Separate the flue ducts To do this remove the adhesive tape 2 Remove the protective foil from both flue ducts 3 Push one flue duct into the other Notes To prevent scratches lay paper over the edges of the lower flue duct to protect the surface Slots of the inner f...

Page 16: ...931001 9000852725 9000852725 Constructa Neff Vertriebs GmbH Carl Wery Straße 34 D 81739 München ...

Reviews: