NEFF D8642N0GB Installation Instructions Manual Download Page 9

9

Prior to installation

Exhaust-air mode

The exhaust air is discharged upwards
through a ventilation shaft or directly
through the outside wall into the open.

D

Exhaust air should neither be directed

into a smoke or exhaust flue that is
currently used for other purposes, nor into
a shaft that is used for ventilating rooms in
which stoves or fireplaces are also located.

Exhaust air may be discharged in 
accordance with official and statutory
regulations only (e.g. national building
regulations).

Local authority regulations must be
observed when discharging air into smoke
or exhaust flues that are not otherwise in
use.

D

When the extractor hood is operated

in exhaust-air mode simultaneously with
a different burner which also makes use
of the same chimney 

(such as gas, oil or

coal-fired heaters, continuous-flow heaters,
hot-water boilers) care must be taken to

ensure that there is an adequate supply
of fresh air 

which will be needed by the

burner for combustion.

Safe operation is possible provided that the
underpressure in the room where the
burner is installed does not exceed 4 Pa
(0.04 mbar).

This can be achieved if combustion air can
flow through non-lockable openings, e.g. in
doors, windows and via the air-
intake/exhaust-air wall box or by other
technical measures, such as reciprocal
interlocking, etc.

If the air intake is inadequate, there is a
risk of poisoning from combustion gases
which are drawn back into the room.

An air-intake/exhaust-air wall box by itself
is no guarantee that the limiting value will
not be exceeded.

Note: When assessing the overall
requirement, the combined ventilation
system for the entire household must be
taken into consideration. This rule does not
apply to the use of cooking appliances,
such as hobs and ovens.

Unrestricted operation is possible if the
extractor hood is used in recirculating
mode – with activated carbon filter.

If the exhaust air is going to be
discharged into the open, 

a telescopic

wall box should be fitted into the outside
wall.

150

150

600/700/900

Summary of Contents for D8642N0GB

Page 1: ...Installation instructions and how to use and look after your built in cooker hoods D8642N0 D8742N0 D8942N0 NEFF UK Ltd...

Page 2: ...2 mind 650 mind 550 Abb 1 ELECTRO Fig 1 GAZ...

Page 3: ...is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When asse...

Page 4: ...or infirmed persons without supervision Young children should be supervised to ensure they do not play with the appliance If the connecting cable for this appliance is damaged the cable must be replac...

Page 5: ...eaned 1 x a month The filters can be cleaned in a dish washer It is however possible that they will become slightly discoloured The filter must be placed loosely and NOT wedged in the dishwasher Impor...

Page 6: ...fuse Filters and maintenance 2 Clean the filters 3 Insert the clean filters back into the hood Activated carbon filter For neutralizing odours in recirculating mode Caution As the filter becomes more...

Page 7: ...t but wipe off with a damp cloth When cleaning the grease filters remove grease deposits from accessible parts of the housing This prevents the risk of fire and ensures that the extractor hood continu...

Page 8: ...iance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment b...

Page 9: ...fresh air which will be needed by the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This ca...

Page 10: ...aller pipe diameters are used the air extraction rate will no longer be at an optimum level and there will be an increase in noise The manufacturer of the extractor hoods accepts no liability for comp...

Page 11: ...ack 3 Connect the brown Live wire to the terminal marked L or coloured red The extractor hood should only be connected to an earthed socket that has been installed according to relevant regulations If...

Page 12: ...hob The bottom edge of the template equates to the lower edge of the extractor hood 4 Drill 4 x l 8 mm holes for the extractor hood and 2 x l 8 mm holes for the chimney panelling Insert plugs into th...

Page 13: ...the flue panelling together slots in the upper section must be pointing downwards and insert into the opening in the extractor hood Protect the cover panels from scratches for example by laying the te...

Page 14: ...14 Notes...

Page 15: ...15 1 2 3 4 5 6 2x 10x 2x 7 361047 Z5123X5...

Page 16: ...9000 152 338 Printed in Germany 0406 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399...

Reviews: