background image

6

Operating procedure

The most effective method of removing kitchen fumes is to:

switch on the extractor hood 

when you start cooking.

switch off the extractor hood 

a few minutes after you finishing cooking.

The fans in this appliance can be switched to the desired setting by hand (manual mode)
or can be controlled fully automatically with the automatic function according to your 
requirements (automatic mode). 

Fan 
on / off

Switching on manual mode:

Press the 

L

or 

+

button.

The fan starts at Setting 

}

.

Switching on the fan settings/intensive
setting:

1.

To increase the fan settings or switch on
the intensive setting 

ç

, press the 

+

button.

The intensive setting operates at
maximum power which should be
used only briefly.
If the intensive setting is not switched
off manually, the fan automatically
switches back to Setting 

}

after 

10 minutes.

2.

To switch off the intensive setting 

ç

or

switch back to fan settings 

~

}

|

and

switch off the extractor hood 
completely, press the 

button.

Switching over to automatic mode:

To switch from manual mode to 
automatic mode at any time, press the 

Ü

button.

Fan – off –
Fan settings – lower –

Fan – on –
Fan settings – higher –

Fan run-on /
Intermittent ventilation

Light 
on / off

Display:

Fan settings / Intensive setting

Saturation – grease filter 

(

#

)

Saturation – activated carbon filter 

(

ã

)

Automatic mode / Manual mode

Summary of Contents for D79T48N0GB

Page 1: ...Installation instructions and how to use and look after your built in cooker hoods NEFF UK Ltd...

Page 2: ...2 Abb 1 ELECTRO Fig 1 GAZ mind 650 mind 550...

Page 3: ...poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the ove...

Page 4: ...nd care of the appliance Please retain the operating and installation instructions for a subsequent owner Gas hobs Gas cookers Do not use all the gas hotplates simultaneously for a prolonged period ma...

Page 5: ...an easily catch fire If you are cooking with fat or oil e g chips etc never leave the cooker unattended Never allow children to play with the appliance Do not let adults or children operate the applia...

Page 6: ...ncrease the fan settings or switch on the intensive setting press the button The intensive setting operates at maximum power which should be used only briefly If the intensive setting is not switched...

Page 7: ...switch from automatic mode to manual mode at any time press the button Intermittent ventilation Used for ventilating the kitchen at hourly intervals at the lowest fan setting round the clock Switchin...

Page 8: ...s long as the dot on the display flashes fan run on is active After 10 minutes the fan switches off and the displays go out Without fan run on Press the L button Sensor control In automatic mode senso...

Page 9: ...In normal operation 1 to 2 hours daily the metal grease filter must be cleaned 1 x a month The filters can be cleaned in a dish washer It is however possible that they will become slightly discoloure...

Page 10: ...lters They can therefore be disposed of as part of your normal domestic refuse Filters and maintenance 3 Engage the catches at both sides 4 Insert the metal grease filters see Removing and inserting t...

Page 11: ...re and ensures that the extractor hood continues operating at maximum efficiency Clean the operating buttons with a mild soapy solution and a soft damp cloth only Do not use stainless steel cleaner to...

Page 12: ...ter the relevant numbers into the box above The E Nr product no and FD production date are shown on the nameplate which can be seen inside the extractor hood after the filter frame has been detached T...

Page 13: ...y manner Please ask your dealer or inquire at your local authority about current means of disposal The extractor hood can be used in exhaust air or circulating air mode Always mount the extractor hood...

Page 14: ...of fresh air which will be needed by the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This...

Page 15: ...m Flat ducts must have an internal cross section that equates to that of round pipes There should be no sharp bends l 120 mm approx 113 cm2 l 150 mm approx 177 cm2 If pipes have different diameters In...

Page 16: ...should only be connected to the electricity supply by a properly qualified electrician A separator must be installed in the household circuit A suitable separator is a switch that has a contact gap o...

Page 17: ...the centre of the location where the hood is going to be mounted 3 Use the template to mark the points on the wall where the screws will be moun ted In order to make it easier to hook the hood onto t...

Page 18: ...brackets at the sides with two screws 1 2 3 08 Screw in the two lower hexagon head cap screws Before the 4 screws are tightened down align the extractor hood properly 09 Stick protective film over th...

Page 19: ...19 Notes...

Page 20: ...20 Notes...

Page 21: ...21 Notes...

Page 22: ...22 Notes...

Page 23: ...23 351210 Z5114X5 1 2 3 4 5 6 2x 10x 2x...

Page 24: ...9000 363 698 Printed in Germany 1208 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399...

Reviews: