12.8 General information
Follow these general instructions during the installation.
¡
For the installation, observe the currently valid build-
ing regulations and the regulations of the local elec-
tricity and gas suppliers.
¡
When discharging the exhaust air, the official and
legal regulations, such as the regional building
code., must be observed.
¡
In order to freely access the appliance for servicing,
select an easy-to-reach installation site.
¡
The surfaces of the appliance are sensitive. Avoid
damaging them during installation.
12.9 Installation
Checking the wall
1.
Check whether the wall is horizontal and adequately
load-bearing.
The maximum weight of the appliance is 40 kg.
2.
Drill the hole depth in accordance with the length of
the screws.
3.
Use the enclosed screws and wall plugs.
The screws and wall plugs enclosed are suitable for
use with solid brickwork. Use suitable fastening
parts for other structures, e.g. plasterboard, porous
concrete, poroton bricks.
4.
Install the appliance with a fixing material which is
sufficiently stable and has been adjusted accord-
ingly for both the structural conditions and the
weight of the appliance.
5.
Check the cut-out area for existing cables of other
appliances.
Preparing the wall
1.
Observe the information on the installation situation.
→
2.
Ensure that there are no electrical wires, gas pipes
or water pipes in the area where holes are to be
drilled.
3.
Cover the hob to prevent damage.
4.
Determine the position of the extractor hood and
lightly mark where the lower edge of the appliance
should be on the wall.
‒
Determine the centre of the hob.
‒
Comply with the safety clearances for the hob.
→
We recommend fitting the extractor hood such that
the lower edge of the glass screen is in line with the
lower edges of the adjacent wall-hung cabinets.
5.
Place the template against the line drawn on the
wall and secure it in place.
6.
Mark the positions for the screws.
7.
For the installation with the flue cover, separate the
template along the marked cut line.
8.
Drill the 8 mm diameter holes to a depth of 80 mm
for the fastenings.
9.
Remove the template.
10.
Insert the wall plugs flush with the wall.
Variant A: Flat extractor hood with flue cover
Variant B: Sloped extractor hood with flue cover
Variant A: Flat extractor hood without flue cover
Variant B: Sloped extractor hood without flue cover
Installing the appliance bracket
1.
Screw on the appliance bracket for the extractor
hood hand-tight.