background image

8

Cleaning and care

Switch off the extractor hood and isola-
te by pulling out the mains plug or swit-
ching off the disconnector on the instal-
lation side.

At the same time as you renew the 
grease filter (see Filters and 
maintenance), clean off any grease from
all accessible parts of the housing.
This significantly reduces the fire hazard
and ensures that the extractor hood 
performs as effectively as possible.

Clean the extractor hood with a hot
detergent solution or a mild window
cleaning agent.

If the hood is extremely dirty (older
stains), use a liquid window cleaner.

Do not scratch off dried-on dirt, but
wipe off with a damp cloth.

Do not use scouring agents.

Warning: 

Clean the control buttons with a

mild detergent solution and a soft, damp
cloth only.

Painted, aluminium and plastic surfaces:

Do not use scouring agents or abrasive
sponges.

Do not use dry cloths.

Do not use corrosive, acidic or alkaline
cleaning agents.

Note:

Do not use alcohol (spirit) on 

plastic parts, otherwise the surface may
become matt in appearance.

Caution! 

Ensure that the kitchen is ade-

quately ventilated. Avoid naked flames.

Changing the bulbs

Candle bulbs:

1.

Switch off the extractor hood and isolate
by pulling out the mains plug or swit-
ching off the disconnector on the instal-
lation side.

2.

Remove the filter frame.

❑ 

See grease filter.

3.

Replace the bulb
(standard filament bulbs, max. 40 watt,
E 14 bulb holder).

4.

Attach the filter frame.

❑ 

See grease filter.

5750.197 475-en  28.09.2004  8:09 Uhr  Seite 8

Summary of Contents for D5625

Page 1: ...Installation instructions and how to use and look after your built in cooker hoods D5625 22 45 and D5855 NEFF UK Ltd...

Page 2: ...ing vapours Exhaust air mode The extractor hood fan extracts the kit chen vapours and conveys them through the grease filter into the atmos phere The grease filter absorbs the solid particles in the k...

Page 3: ...you are cooking with fat or oil e g chips etc never leave the cooker unattended Do not flamb food directly under the extractor hood Risk of grease filter catching fire due to flames Before using your...

Page 4: ...er the filter becomes increasingly inflammable The efficiency of the extractor hood can also be adversely affected Important Renewing the fleece filter at appropriate intervals prevents the possibilit...

Page 5: ...filter Under normal operating conditions 1 to 2 hours per day the metal grease filter will require cleaning after 8 to 10 weeks The filter can be cleaned in a dishwasher This can however cause slight...

Page 6: ...ease filter by pulling it towards yourself 2 Clean the grease filters 3 Re insert the clean grease filters Removing and installing the activa ted carbon filter Extractor hoods with a filter mat 1 Remo...

Page 7: ...ssories on the last page Use original filters only This will ensure optimum performance Disposing of the old activated carbon filter Activated carbon filters do not contain any pollutants They can be...

Page 8: ...off with a damp cloth Do not use scouring agents Warning Clean the control buttons with a mild detergent solution and a soft damp cloth only Painted aluminium and plastic surfaces Do not use scouring...

Page 9: ...ff there is still a risk of burns 2 Remove the bulb ring with a screwdriver or similar tool 3 Replace the halogen light bulb conventional halogen bulb 12 Volt max 20 Watt G4 cap Caution Refer to for p...

Page 10: ...d must not be installed over a solid fuel cooker a potential fire hazard e g flying sparks unless the cooker features a closed non removable cover and all national regulations are observed The smaller...

Page 11: ...ow through non closeable openings such as in doors windows wall ventilation boxes or by alternative technical measures such as reci procally shutting the other device off etc If the air intake is inad...

Page 12: ...page into the air pipe connector and then attach the exhaust air pipe 120 mm extraction pipe Attach the exhaust air pipe directly to the air pipe connector Extractor hoods with 150 mm air outlet 150 m...

Page 13: ...d person in order to prevent a hazardous situation Improper repairs may put the user at considerable risk Length of connection cable 1 20 m Electrical specifications The electrical specifications can...

Page 14: ...48 100 35 225 min 15 m in 15 500 3 16 352 3 Extractor hood with slide control 73 cm wide 1 and 2 motor 9 346 160 55 95 150 120 348 348 100 35 225 380 730 min 15 m in 15 16 352 3 700 3 Installation 310...

Page 15: ...s 1 Loosen the screws 2 Hold the underside of the extractor hood Hold the underside of the extrac tor hood 3 Lower the extractor hood and remove Installation Installation spring Weight in kg Width 53...

Page 16: ...280 530 280 530 380 530 730 380 530 730 280 530 380 530 730 380 530 730 380 530 730 380 530 730 Z 5154X0 Z 5155X0 461423 481051 095660 5750 197475 Printed in Germany 1004 Hi...

Reviews: