background image

en

    Operating the appliance

6

1

Operating the appliance

Operating

 the appl

iance

These instructions apply to several appliance variants. It 

is possible that individual features are described which 

do not apply to your appliance.

Note: 

Switch on the extractor hood when you start 

cooking and switch it off again several minutes after you 

have finished cooking. This is the most effective way of 

removing the kitchen fumes.

Control panel

Setting the fan

Switching on

Pull out the filter pull-out and touch the 

#

 symbol.

The fan will start at setting 

ƒ

.

Touch the + or - symbol to alter the fan speed.

Note: 

When the filter pull-out is pushed in, only fan 

settings 

ƒ

 and 

 can be selected.

Switching off

Touch the 

#

 symbol. Slide in the filter pull-out.

Intensive setting

You can use the intensive setting if there is a large 

build-up of odours and fumes/vapours.
Touch the 

˜

 symbol. 

˜ƒ

 appears on the display. Touch 

the - symbol to switch back to the 

˜‚

 intensive setting.

After approximately six minutes, the electronics 

automatically reduce the fan to a lower setting . If you 

want to end the intensive setting before the preset time 

expires, touch the 

˜

 symbol.

Fan run-on time

Press - until the 

9

 symbol appears, or slide in the filter 

pull-out.
After approximately 10 minutes, the fan will switch off 

automatically.

Automatic mode

Switching on

Touch the 

#

 symbol.

The fan starts at setting 

ƒ

.

Touch the 

 symbol.

The optimum fan setting 

‘‚

‘ƒ

 or 

‘„

 is 

automatically set via a sensor.

Switching off

Touch the 

 or 

#

 symbol to switch automatic mode off.

The fan switches off automatically if the sensor no 

longer detects a change in the air quality of the room.
Automatic mode can run for a maximum of four hours.

Sensor control

In automatic mode, a sensor in the extractor hood 

detects the intensity of the cooking and roasting 

odours. Depending on the sensor setting, the fan 

automatically switches to another fan setting.
Default sensitivity setting: 

Lowest sensitivity setting: 

Highest sensitivity setting: 

Š

If the sensor control responds too quickly or too slowly, 

it can be changed accordingly:

1.

Press and hold the 

 symbol for approximately four 

seconds when the fan is switched on. The setting is 

displayed.

2.

The sensor control setting can be changed by 

touching the + or - symbol.

3.

To confirm the entry, press and hold the 

 symbol 

for approximately four seconds.

AirFresh function

Touch the 

 symbol until the 

 3

 appears. The 

fan runs for approximately five minutes per hour.
Touch the 

3

 symbol if you want to end the AirFresh 

function.

Explanation

#

Fan on/off

4

Noise reduction

3

AirFresh function

-

Reduces the fan settings

+

Increases the fan settings

˜

Intensive setting

Automatic function

6

Light on/off/dimming

Summary of Contents for D46PU64X0

Page 1: ...en Instructions for installation and use Extractor hood...

Page 2: ...location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufac...

Page 3: ...oming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitab...

Page 4: ...les replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales s...

Page 5: ...s Operatingmodes Exhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain hea...

Page 6: ...tely 10 minutes the fan will switch off automatically Automatic mode Switching on Touch the symbol The fan starts at setting Touch the symbol The optimum fan setting or is automatically set via a sens...

Page 7: ...filter changed For instructions on how to clean the metal grease filters please refer to the section Cleaning and maintenance The saturation indicator can be reset while it is flashing To do this tou...

Page 8: ...ase filter may catch fire Clean the grease filter at least every 2 months Never operate the appliance without the grease filter Notes Do not use any aggressive acidic or alkaline cleaning agents When...

Page 9: ...esh grease filter upwards locking it in place 3Trouble shooting Troubleshooting Malfunctions often have simple explanations Please read the following notes before calling the after sales service Warni...

Page 10: ...ionalism of the manufacturer You can therefore be sure that the repair is carried out by trained service technicians who carry original spare parts for your appliances Accessories not included in the...

Page 11: ...dual features are described which do not apply to your appliance This appliance is installed in a upper cabinet Follow the enclosed installation instructions for additional special accessories e g for...

Page 12: ...pendent heat producing appliance is being operated Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air...

Page 13: ...tallation side with a contact gap of at least 3 mm The fixed connection must only be installed by an electrician Warning Danger of suffocation Packaging material is dangerous to children Never allow c...

Page 14: ...the units The fitted unit must be level and have sufficient load bearing capacity The max weight of the extractor hood is 18 kg Appliance dimensions and safety clearances Observe the appliance s dimen...

Page 15: ...to the body on the left and right 3 Remove the tabs from the bottom of the mounting pieces Preparing the appliance Connect the power cord provided to the appliance 5Installation Installation Sliding t...

Page 16: ...doing this grip the bottom of the appliance with the other hand Caution Push in the fastening bolt gently with your fingers and turn it until it comes out of the housing with the spring 3 Carefully r...

Page 17: ...the appliance s handle strip flush with the fitted unit 1 Pull the filter pull out towards you 2 Shorten the spacer to the required dimension and insert it into the slot specified Connecting the pipes...

Page 18: ...6...

Page 19: ...6...

Page 20: ...www neff international com 9001086782 9001086782 950827 Constructa Neff Vertriebs GmbH Carl Wery Stra e 34 D 81739 M nchen Register your product online...

Reviews: