14
Operating modes
This appliance can be used in exhaust-air mode or circulating-
air mode.
Exhaust air mode
Note.
The exhaust air must not be conveyed into a functioning
smoke or exhaust gas flue or into a shaft which is used to
ventilate installation rooms which contain heat-producing
appliances.
■
Before conveying the exhaust air into a non-functioning
smoke or exhaust gas flue, obtain the consent of the heating
engineer responsible.
■
If the exhaust air is conveyed through the outer wall, a
telescopic wall box should be used.
Circulating-air mode
Note:
To bind odours in circulating-air mode, you must install
an activated carbon filter. The different options for operating the
appliance in circulating-air mode can be found in the brochure.
Alternatively, ask your dealer. The required accessories are
available from specialist outlets, from customer service or from
the Online Shop. The accessory numbers can be found at the
end of the instructions for use.
Operating the appliance
These instructions apply to several appliance variants. It is
possible that individual features are described which do not
apply to your appliance.
Note:
Switch on the extractor hood when you start cooking and
switch it off again several minutes after you have finished
cooking. This is the most effective way of removing the kitchen
fumes.
Control panel
Setting the fan
Note:
Always adjust the fan strength to meet current conditions.
If there is a large build-up of steam or fumes, select a high fan
setting.
Switching on the appliance
1.
Press the
#
button.
The fan starts at setting 1.
2.
Press the "+" or "-" buttons to set another fan setting.
Switching off the appliance
Press the 0 button.
Intensive setting
You can use the intensive setting if there is a large build-up of
odours and fumes/vapours.
1.
Press the
˜
button.
The intensive setting
˜‚
is activated.
2.
Press the
˜
button.
The intensive setting is deactivated.
Note:
The intensive setting run time is 6 minutes. Once this
time has elapsed, the appliance switches back to the
ƒ
fan
setting.
Fan run-on time
1.
Press the
9
button.
The current fan setting and the remaining run-on time in
minutes are displayed alternately in the display panel. The fan
continues to run at the previous setting for 15 minutes. Once
this time has elapsed, the ventilation and lighting
automatically switch off.
2.
Press the
9
button.
The fan run-on ends before the end of the remaining run-on
time.
The air which is drawn in is cleaned by the
grease filters and conveyed to the exterior
by a pipe system.
The air which is drawn in is cleaned by the
grease filters and an activated carbon filter and
conveyed back into the kitchen.
Explanation
1
Switch the fan on/off
2
Switch on the fan run-on
3
Switch on the interval ventilation
4
Turn the fan down
5
Display panel
6
Switch up the fan setting
7
Switch on intensive mode
8
Reset the saturation indicator
9
Switch on the lighting