25
Connecting a
l
150 mm exhaust-air
pipe:
❑
Mount the pipe directly onto the air
outlet on the hood.
Connecting a
l
120 mm exhaust-air
pipe:
❑
Insert the reducing connector into the air
connector, drill 2x
l
3 mm holes and
screw together.
Prior to installation
For optimum extractor hood efficiency:
❑
Short, smooth air exhaust pipe.
❑
As few bends in the pipe as possible.
❑
Diameter of pipe to be as large as
possible and no tight bends in pipe.
If long, rough exhaust-air pipes,
many pipe bends or smaller pipe
diameters are used, the air extraction
rate will no longer be at an optimum
level and there will be an increase in
noise.
❑
Round pipes:
We recommend
Internal diameter:
150 mm
(at least
120 mm).
❑
Flat ducts
must have an internal cross-
section that equates to that of round
pipes.
There should be no sharp bends.
l
120 mm approx. 113 cm
2
l
150 mm approx. 177 cm
2
❑
If pipes have different diameters:
Insert sealing strip.
❑
For exhaust-air mode,
ensure that
there is an adequate supply of fresh air.
Circulating-air mode
❑
With activated carbon filter if exhaust-air
mode is not possible.
❑
Attach the exhaust-air pipe to the
reducing connector.
The complete
installation set can be
obtained
from
specialist
outlets.
The corresponding
accessory numbers
can be found at the
end of these operating
instructions.
250
350
580
565
100
50
520
900
390
630
mind. 120
775-1220
mind.
450
mind.
550
Summary of Contents for D 99T5N0
Page 81: ...81 D 4 Pa 0 04 mbar...
Page 82: ...82 T E 15 A...
Page 83: ...83 0 3 0 Off 10 10 a a 3 3...
Page 84: ...84 10 D 2 3 8 10 2 3 4 0 1...
Page 85: ...85 Filtros e manuten o 3 4 5 0 3 1 2 1 10 A 1 2 1 2...
Page 86: ...86 3 12 Volt 20 Watt G4 4 5 1 2...
Page 87: ...87 1 FD...
Page 88: ...88 TRGI 50 mm 650 mm 1 D 550 mm 1 D...
Page 93: ...93 10 11 12 15 14 2 08 4 09 2 13 1 2 3 1 2...
Page 94: ...94 Notizen...