Installation
The extractor hood
is designed to be
fitted to the kitchen ceiling or a rigid
suspended ceiling.
Ensure that the minimum distance
between hotplate and extractor hood is
550 mm
for electric hotplates and
650 mm
for gas hotplates.
1.
Mark the centre point of the extractor
hood on the ceiling.
2.
Using the template, mark screw
positions on the ceiling.
3.
Drill 4x 8 mm holes and insert wall plugs
flush with the ceiling.
4.
Determine the overall height of the
support frame.
– This is the height of the ceiling, the
height of the base and the distance
between the hob and extractor hood.
Exhaust air
430 - 710
Circulating air
430 - 750
min. 550 electric
650 gas