background image

Neets Control – OsCar 

Installation Manual

Summary of Contents for OsCar

Page 1: ...Neets Control OsCar Installation Manual...

Page 2: ...otice Questions AFTER reading this manual can be addressed to your local dealer or Neets by E Mail Support Neets dk or you may use our contact form at www neets dk Revision list Author Date Descriptio...

Page 3: ...components inside These openings must never be blocked by other objects Do not use this equipment near water To reduce the risk of fire or electric shock do not expose this apparatus to rain or moistu...

Page 4: ...nt safety instructions 3 Contents 4 Description 5 Quick guide to the OsCar 6 Installation 7 DK Version 7 EU version 8 Connections and Controls 9 Power input port 9 I O Ports 9 IR RS 232 port 10 Button...

Page 5: ...t up a presentation without an introduction just press ONE button and you are ready to begin Neets Control OsCar is easy to install and perfect for use in classrooms Function description RS 232 Tx Rx...

Page 6: ...hts for indication of AV setup status 3 Front cover with label for button description 4 Mini USB for programming behind front cover Rear Number Description 1 External 12V DC input 2 RS 232 or IR contr...

Page 7: ...on the bracket DK version Insert a flathead screwdriver gently and pry out the front cover Remove the front cover and the paper label behind it Insert a flathead screwdriver into the button Gently pus...

Page 8: ...ket into the two holes Secure the control system to the back box or bracket without overtightening the screws Remount the paper label insert a printed transparent label showing the button func tions a...

Page 9: ...ich means you will need external relays if you need to prevent e g ground loops When used as output it is active low when the software says activated the pin are tied to GND through a FET transistor a...

Page 10: ...r activation Also each button has an embedded red LED light to indicate current status of the AV system Button function and LED indication are set up using the Neets Project Designer software Configur...

Page 11: ...n off the power to the control system for 20 sec before turning the power on again 1 Off 2 Off 3 Flashing 4 Off Error in serial number o You need to return the unit to Neets or your local dealer for r...

Page 12: ...6 2 FCC Part 15 Class A CE Input Output Ports 2 x I O Input trigger low 1VDC Input trigger high 4VDC Output type Open drain Isolated output No Max voltage load 24 VDC Max current 0 5 A Connector 3 pi...