background image

 

Page

 

9

  

 

Doc.

 

no#:

 

310

0300

001

002

 

R200

 

Manual

 

 

  

Fault

 

finding

 

 

When

 

errors

 

occur

 

the

 

LED

 

will

 

indicate

 

this.

 

The

 

following

 

will

 

give

 

you

 

a

 

guide

 

to

 

find

 

these

 

errors.

 

In

 

the

 

Neets

 

Control

 

 

AlFa

 

the

 

LED´s

 

are

 

placed

 

here:

 

 

 

 
 

Fault

 

 

Solution

 

 

SD

 

card

 

missing

 

 

 

Control

 

that

 

the

 

SD

 

card

 

is

 

mounted

 

correctly

 

and

 

that

 

the

 

µSD

 

card

 

that

 

you

 

are

 

using

 

are

 

formatted

 

with

 

FAT.

 

 

Unexpected

 

Error

 

 

 

There

 

are

 

properly

 

problems

 

in

 

the

 

project

 

you

 

have

 

uploaded.

 

Try

 

e.g.

 

to

 

upload

 

a

 

empty

 

project

 

and

 

see

 

if

 

this

 

works

 

or

 

contact

 

Neets

 

or

 

you

 

dealer

       

 

Error

 

in

 

serial

 

number

 

 

 

Doing

 

the

 

production

 

of

 

the

 

unit,

 

something

 

has

 

gone

 

wrong.

 

You

 

need

 

the

 

return

 

the

 

unit

 

to

 

Neets

 

or

 

your

 

dealer

 

for

 

replacement/repair.

  

 

Unzipping

 

config.zip

 

file

 

after

 

power

 

on

 

 

 

If

 

you

 

manually

 

have

 

placed

 

a

 

project

 

file

 

on

 

the

 

µSD

 

card

 

the

 

system

 

will

 

extract

 

the

 

files

 

needed

 

to

 

run

 

the

 

project.

 

After

 

extraction,

 

the

 

system

 

will

 

start

 

to

 

run

 

the

 

project.

 

 

Unable

 

to

 

start

 

the

 

project

 

 

 

This

 

scenario

 

often

 

happens

 

when

 

the

 

µSD

 

card

 

in

 

the

 

unit

 

are

 

replaced

 

with

 

a

 

blank

 

µSD

 

card.

 

Alternative

 

there

 

can

 

be

 

a

 

problem

 

in

 

the

 

project

 

you

 

have

 

uploaded.

 

Try

 

e.g.

 

to

 

upload

 

a

 

empty

 

project

 

and

 

see

 

if

 

this

 

works

 

or

 

contact

 

Neets

 

or

 

you

 

dealer

       

 

System

 

are

 

in

 

boot

 

mode

 

 

 

You

 

have

 

put

 

the

 

system

 

in

 

boot

 

mode.

 

This

 

mode

 

allows

 

you

 

to

 

communicate

 

with

 

the

 

system

 

using

 

Rx1/Tx1.

 

See

 

the

 

section

 

“Switch

 

and

 

LED”

 

on

 

page

 

7

 

for

 

details

 

on

 

how

 

to

 

get

 

the

 

system

 

into

 

boot

 

mode.

  

 

Setting

 

the

 

system

 

into

 

factory

 

default

 

mode.

 

System

 

are

 

resuming

 

factory

 

default

 

settings

 

 

When

 

pressing

 

Switch

 

1

 

and

 

4

 

during

 

power

 

on

 

the

 

system

 

will

 

delete

 

the

 

current

 

settings

 

and

 

resume

 

factory

 

default.

  

This

 

method

 

are

 

only

 

intended

 

to

 

be

 

used

 

if

 

the

 

control

 

system

 

lock

 

up

 

and

 

enter

 

“Unexpected

 

Error”

    

Summary of Contents for Alfa

Page 1: ......

Page 2: ...y third party access to content information or data in this manual without Neets express written consent CHANGES Neets reserve the right to change the specification and functions of this product witho...

Page 3: ...t 2 Description 3 Connections to the unit 4 Technical description 5 USB 5 Power output 5 Time Battery RTC 5 RS 232 Port 6 IR RS 232 ports 6 uSD Card 6 Switch and LED 7 I O Ports 7 LAN 7 Build in relay...

Page 4: ...ith LAN access enabled complete systems can be controlled from another room or even off site The compact 1U rack mount frame provides status monitoring with front panel LED indicators and the rear pan...

Page 5: ...or LED indication 3 Power connected LED indicator 4 110 230 VAC power in 5 Fuse for control system NOT for screen 6 Cliff connector for 230Vac screen control NOT fused 7 Potential free relays 8 Extern...

Page 6: ...while programming so always remember to connect the 230 VAC power The USB connector needed to connect to the Neets Control AlFa is of the type mini USB B 5P You can buy this cable on the web buy a USB...

Page 7: ...t can be configured in software either as RS 232 or as IR emitter uSD Card The uSD Card is used to storage firmware homepage and settings Under normal operation removal of the uSD Card is not needed I...

Page 8: ...ou will need external relays if you need to prevent e g ground loops When used as output they are active low when the software says activated the pin are tied to GND thru a FET transistor also called...

Page 9: ...for controlling 230 VAC screens and lifts By using the included Cliff connector you get an easy connection of your screen or lift and a high level of security against short circuit The relay 3 is con...

Page 10: ...project file on the SD card the system will extract the files needed to run the project After extraction the system will start to run the project Unable to start the project This scenario often happen...

Page 11: ...e you the best support possible we recommend that you have access to the log file when contacting support There are two ways to get access to this file uSD card If you put the uSD card into your compu...