Manual
Fault
finding
When
errors
occur
the
LED
will
indicate
this.
The
following
will
give
you
a
guide
to
find
these
errors.
In
the
Neets
Control
–
AlFa
the
LED´s
are
placed
here:
Fault
Solution
SD
card
missing
Control
that
the
SD
card
is
mounted
correctly
and
that
the
µSD
card
that
you
are
using
are
formatted
with
FAT.
Unexpected
Error
There
are
properly
problems
in
the
project
you
have
uploaded.
Try
e.g.
to
upload
a
empty
project
and
see
if
this
works
or
contact
Neets
or
you
dealer
Error
in
serial
number
Doing
the
production
of
the
unit,
something
has
gone
wrong.
You
need
the
return
the
unit
to
Neets
or
your
dealer
for
replacement/repair.
Unzipping
config.zip
file
after
power
on
If
you
manually
have
placed
a
project
file
on
the
µSD
card
the
system
will
extract
the
files
needed
to
run
the
project.
After
extraction,
the
system
will
start
to
run
the
project.
Unable
to
start
the
project
This
scenario
often
happens
when
the
µSD
card
in
the
unit
are
replaced
with
a
blank
µSD
card.
Alternative
there
can
be
a
problem
in
the
project
you
have
uploaded.
Try
e.g.
to
upload
a
empty
project
and
see
if
this
works
or
contact
Neets
or
you
dealer
System
are
in
boot
mode
You
have
put
the
system
in
boot
mode.
This
mode
allows
you
to
communicate
with
the
system
using
Rx1/Tx1.
See
the
section
“Switch
and
LED”
on
page
7
for
details
on
how
to
get
the
system
into
boot
mode.
Setting
the
system
into
factory
default
mode.
System
are
resuming
factory
default
settings
When
pressing
Switch
1
and
4
during
power
on
the
system
will
delete
the
current
settings
and
resume
factory
default.
This
method
are
only
intended
to
be
used
if
the
control
system
lock
up
and
enter
“Unexpected
Error”