6
Manual drainage
1. The ‘water full’ indicator flashes and the product emits an alarm
sound to indicate that the water reservoir is full.
2. Switch off the product using
B
q
3. Unplug
A
y
.
4. Place a water container underneath
A
t
.
5. Remove the water plug of
A
t
6. Slightly tilt the product backwards to ensure all water leaves the
reservoir.
7. Put the water plug back on
A
t
Declaration of Conformity
We, NEDIS, as manufacturer, declare that product ACMB1WT14 from
the brand Nedis, produced in China was tested according to all
relevant CE standards / regulations and passed all tests.
The complete Declaration of Conformity ( + safety datasheet if
applicable ) can be found and downloaded via http://webshop.
nedis.com
For other compliant-related information, please contact customer
service desk for support:
via website: http://www.nedis.com
via e-mail: [email protected]
NEDIS B.V., De Tweeling 28,
5215 MC ’s-Hertogenbosch, THE NETHERLANDS
c
Kurzanleitung
Mobile 3-in-1-Klimaanlage
ACMB1WT14
Weitere Informationen finden Sie in der erweiterten
Anleitung online:
ned.is/acmb1wt14
Bestimmungsgemäße Verwendung
Die Nedis ACMB1WT14 ist eine lokale Klimaanlage zum Kühlen und
Entfeuchten von Räumen.
Das Produkt ist ausschließlich zur Verwendung als lokale
Klimaanlage für den Hausgebrauch zum Einsatz in Innenräumen
gedacht.
Das Produkt ist nicht für den professionellen Einsatz gedacht.
Kinder ab dem achten Lebensjahr und Personen mit
eingeschränkten körperlichen, sensorischen oder geistigen
Fähigkeiten oder ohne ausreichende Erfahrung und Kenntnis dürfen
dieses Produkt nur dann verwenden, wenn sie beaufsichtigt werden
oder in die sichere Benutzung des Produkts eingewiesen wurden
und die bestehenden Gefahren verstehen. Kinder dürfen nicht mit
dem Produkt spielen. Reinigung und Wartung durch den Benutzer
dürfen nicht von unbeaufsichtigten Kindern durchgeführt werden.
Das Produkt ist zur Verwendung in Haushaltsumgebungen
für typische Haushaltsfunktionen gedacht, die auch von nicht
fachkundigen Benutzern ausgeführt werden können, wie z. B.:
in Geschäften, Büros und ähnlichen Arbeitsumgebungen,
Bauernhäusern, von Kunden in Hotels, Motels und anderen
Unterkünften und/oder in Pensionen.
Jegliche Modifikation des Produkts kann Folgen für die Sicherheit,
Garantie und ordnungsgemäße Funktionalität haben.
Spezifikationen
Produkt
Mobile 3-in-1-Klimaanlage
Artikelnummer
ACMB1WT14
Größe (L x B x H)
390 x 480 x 760 mm
Gewicht
33.5 kg
Eingangsspannung
220 – 240 V ~ 50 Hz
Erforderliche Leistung
1610 W
4. Assemble the window kit
A
6
the fasteners
A
7
.
5. Install
A
6
in the window opening.
4
The window kit can be placed in horizontal and vertical
direction.
6. Tighten
A
7
.
7. Snap
A
4
into
A
6
and fasten with the exhaust nozzle screw
A
o
.
Assembling the continuous drainage (optional)
-
Works only in dehumidifying and heating mode.
1. Open the continuous drainage outlet
A
w
.
2. Connect
A
w
to a water container or drainage system (not
included).
Placing the batteries in the remote control
1. Slide the battery cover off the back of the remote control
A
i
2. Insert 2 type AAA batteries.
3. Slide the battery cover back in place on
A
i
Using the control panel and remote control
(image B)
Button
Function
Timer button
B
1
Press to set the timer. Use
B
5
and
B
7
to set the duration of cooling.
Mirage Button
B
2
Press to switch on the hidden display
on the front. Press again to turn off
the display.
Mode selection button
B
3
Repeatedly press the button to
select the mode: Cooling mode /
Dehumidifying mode / Fan mode.
Sleep mode button
B
4
Activate sleep mode. Only works in
cooling mode. After one hour the set
temperature increases 1 °C and again
after 2 hours.
Temperature up button
B
5
Increase values.
Temperature down
button
B
7
Decrease values.
Fan speed button
B
8
Press repeatedly to select the fan
speed.
(Not available in sleep and
dehumidifying mode).
Swing button
B
9
Switch the oscillation on or off.
Change the orientation of the louvers.
Power button
B
q
Switch the product on or off.
Temperature button
B
w
Switch between Celsius and
Fahrenheit.
Frost protection function
•
The product automatically enters the frost protection status if the
temperature of the exhaust pipe is too low. (only works in cooling
mode).
•
The product automatically reverts to the normal operation if the
temperature of the exhaust pipe rises to a certain temperature.
Protection function of the compressor
•
To increase the lifetime of the compressor, it has a 3 minute delay
booting protection function after the compressor is switched off.
Overflow protection function
•
If water exceeds the warning level, the product emits a tone, and
the ‘water full’ indicator starts flashing.
(See next paragraphs how to empty the water reservoir of the
product.)