FilterBox
EN
4 Installation
Read
Section 2.2 General safety instructions
before
installing the product.
4.1 Mount FilterBox to wall or floor
stand
For wall or floor stand mounted FilterBox, be
sure to provide enough working space around
the unit for services such as filter cleaning and
replacement.
4.1.1 Floor stand
See
Use appropriate bolts and plugs for the surface.
4.1.2 Wall
See
Use appropriate bolts and plugs for the surface.
The bolts must each stand stress of at least
2100 N.
4.2 Attach fan package
See
.
• Connect the cable from the motor to the fan.
On 3-phase fans, make sure the fan rotates in
the direction of the arrow, see
. If the
fan rotates in the wrong direction, switch the
connection for two of the cables.
4.3 Attach collector bin
See
. Nederman recommends the use of
plastic bags in the collector bin for better dust dispos-
al.
• When using a plastic bag, a pressure equalization
tube must be connected to the collector bin, see
, items 4 and 5.
If no bag is used, tie a knot to seal the cable,
see
, item 4.
4.4 Connect arm
See;
• User manual: Original Series 535
• Mounting instruction: Extraction Arm Original Light
Package
4.5 Connect compressed air
See
CAUTION!
Use clean air according to DIN ISO 8573-1, class
5/5/4 (250 l/min, 7 Bar).
4.6 Automatic filter cleaning
Automatic filter cleaning occurs when the pressure
drop across the filter reaches a standard preset value.
FilterBox goes into idle mode before the filter clean-
ing process begins.
If the preset value is reached during use, the
product goes into idle mode and starts filter
cleaning.
• To set up automatic filter cleaning [ON/OFF],
see
4.7 Filter cleaning with a preset time in-
terval
For certain applications, it may be preferable to use
filter cleaning with a preset time interval. Filter clean-
ing starts when the unit is in idle mode and not being
.
4.8 Connect tools to control panel
Compressed air and electrical tools can be connected
to the outlets J (1-phase) and K, see
• To connect a welding clamp, see
By default, the FilterBox fan automatically starts
when a tool connected to one of these outlets is used.
But, this feature can be disabled in item 5 ‘A/M fan
start’ in the menu.
• To prevent the fan from stopping during short
pauses in work, a time delay can be set up in menu
“1. Fan off delay”.
• Set up autostart of fan [ON/OFF], see
.
• Set up time delayed fan stop [1–60 min], see
5 Use FilterBox
Section 2.2 General safety instructions
before
using the product.
Position the extractor arm hood correctly, see
.
5.1 Start FilterBox
.
1 Turn the main power switch L to ON.
2 Start FilterBox with the button S1, or switch on
extractor arm hood.
5.2 Overload protector
FilterBox is equipped with an overload protector that
automatically disconnects the power if the fan motor
becomes overloaded. For a list of possible causes, see
the FilterBox Installation and Service Manual.
22