Nederman 512337 Instruction Manual Download Page 14

Manufacturer:

AB Ph. Nederman & Co

Sydhamnsgatan 2
SE-252 28 Helsingborg, Sweden
Telephone: Int. +46 42 18 87 00
Fax: Int.+46 42 14 79 71
www.nederman.se
E-mail: [email protected]

Summary of Contents for 512337

Page 1: ...ENGLISH NO 148 317 01 2000 03 09 Fan Starter INSTRUCTION MANUAL Fan Starter 4 4 kW 400 V 3 N 50 Hz ART NO 512337 ...

Page 2: ...ormity 3 Safety 4 Technical data 4 Accessories 4 Description 4 Installation 6 Component list 7 Lay out 8 Main circuits diagram 9 Control circuits diagram 10 Interconnection diagram general 11 Interconnection diagram OPTION 12 Interconnection diagram FILTERMAX 13 ...

Page 3: ...or other normative documents EN 50 081 1 EN 50 082 2 EN 60 439 1 following the provisions of Directive 89 336 EEC 92 31 EEC 73 23 EEC AB Ph Nederman Co Sydhamnsgatan 2 S 252 28 Helsingborg Sweden 1999 12 21 ________________________________ Magnus Hammarlund Product Manager SAFETY Warning Only a competent electrician may install the Fan Starter Warning If start signal is activated the fan will auto...

Page 4: ... Starter 4 is a direct starter for Nederman NCF Fans The Fan Starter is fitted with a 4 pole main switch interlocked with the door so that the door can not be opened if the switch is on Control voltage is 24 V AC supplied by an internal transformer The Fan Starter is prepared for connection with different components in an extraction system If Neutral is connected N a single phase supply of 230 V i...

Page 5: ...n Starter With FILTERMAX the remote impulse start and stop can not be connected The white indication lamp indicates running fan The yellow fault indication lamp indicates basically tripped motor overload protector with FILTERMAX it indicates the ALARM signal service or A Alarm Tripped motor overload protector will be indicated on the FILTERMAX Control panel with a red lamp at the fan symbol The st...

Page 6: ...protection For terminals 3 114 use minimum 1 5 mm2 if cable is up to 10 m long and minimum 2 5 mm2 if cable is up to 20 m long Larger area if cable is longer The current value for the motor overload protector has to be set For the direct starter set the value to the motor current at 400 V See the motor plate Connect the motor in accordance with the power circuit diagram Check the fan direction A s...

Page 7: ...ourth Pole Shaft Actuator Allen Bradley 194E A25 1753 194E A25 NP 164L 3393 194L HE6G 175 Q2 Circuit breaker Terasaki TDD II 1 S 2 pole 1 A Q3 Circuit breaker Terasaki TDD I 6 S 1 pole 6A Q4 Circuit breaker Terasaki TDD I 6 S 1 pole 6 A S1 Selector Switch Operator Latch Contact Block Allen Bradley 800EP SM32 800E A3L 800E 3X10 T1 Transformer ETV Åkarp 09703 400 24 V 150 VA X1 Terminal Row Allen Br...

Page 8: ...Fan Starter 4 36 ...

Page 9: ...Fan Starter 4 37 ...

Page 10: ...38 Fan Starter 4 ...

Page 11: ...Fan Starter 4 39 ...

Page 12: ...Fan Starter 4 40 ...

Page 13: ...Interconnection diagram FILTERMAX 41 Fan Starter 4 ...

Page 14: ...Manufacturer AB Ph Nederman Co Sydhamnsgatan 2 SE 252 28 Helsingborg Sweden Telephone Int 46 42 18 87 00 Fax Int 46 42 14 79 71 www nederman se E mail support nederman se ...