Nedap WIM Quick Reference Manual Download Page 3

WIM | QUICK REFERENCE GUIDE 

 

 

3/4 

CONNECTIONS 

Front side 

 

 

 

RS485 

Connect the RS485 to the License Plate Reader (9600, 8N1). 
B: 

RS485-B (green) 

A: 

RS485-A (yellow) 

GND: 

RS485-GND (purple) 

Wiegand 

Connect the Wiegand output to your access control system. 
D1: 

Wiegand data-1 (white) 

D0: 

Wiegand data-0 (green) 

GND: 

Ground (black) 

Magstripe 

Magstripe Clock and Data output. Select with the plate conversion mode switches. See below. 
D1: 

Data 

D0: 

Clock 

CLS: 

Card Loaded 

GND: 

Ground 

Barcode 

Barcode wand emulation data output in code39 format. Select with conversion mode 
switches. See below. 
D1: 

Wand emulation data output (black=high) 

D0: 

Wand emulation data output (black=low) 

GND: 

Ground (black) 

STS LED 

Status LED (green) 

ERR LED 

Error LED (red) 

LAN 

The LAN connection (RJ45 socket) is used to configure the device and manage the match-list. 
Link LED (left): 

 

Off=No link, Amber=10Mbps,  

 

 

 

 

  

 

Green=100Mbps. 

Activity LED (right): 

Off=No activity, Amber=HDX Activity,  

 

 

 

  

 

Green=FDX Activity. 

 

 

 

RS485 

connection 

WIEGAND 

output 

LED 

indications 

LAN 

connection 

G

ND

 

CL

D0

 

D1

 

G

ND

 

A

 

B

 