WIM | QUICK REFERENCE GUIDE
3/4
CONNECTIONS
Front side
RS485
Connect the RS485 to the License Plate Reader (9600, 8N1).
B:
RS485-B (green)
A:
RS485-A (yellow)
GND:
RS485-GND (purple)
Wiegand
Connect the Wiegand output to your access control system.
D1:
Wiegand data-1 (white)
D0:
Wiegand data-0 (green)
GND:
Ground (black)
Magstripe
Magstripe Clock and Data output. Select with the plate conversion mode switches. See below.
D1:
Data
D0:
Clock
CLS:
Card Loaded
GND:
Ground
Barcode
Barcode wand emulation data output in code39 format. Select with conversion mode
switches. See below.
D1:
Wand emulation data output (black=high)
D0:
Wand emulation data output (black=low)
GND:
Ground (black)
STS LED
Status LED (green)
ERR LED
Error LED (red)
LAN
The LAN connection (RJ45 socket) is used to configure the device and manage the match-list.
Link LED (left):
Off=No link, Amber=10Mbps,
Green=100Mbps.
Activity LED (right):
Off=No activity, Amber=HDX Activity,
Green=FDX Activity.
RS485
connection
WIEGAND
output
LED
indications
LAN
connection
G
ND
CL
S
D0
D1
G
ND
A
B