VP1006-200PM-00-OEM ISO Reader
4-2007/1.0 Page 6 of 9
CP-menu communication possibilities
RS232 with Nedap extened protocol
RS232
20
Nedap extened protocol 2400 Baud
21
Nedap extened protocol 9600 Baud
22
Nedap extened protocol 19200 Baud
23
Nedap extened protocol 38400 Baud
24
RS485 with Nedap extened protocol
RS485
Bias off - no. of breaks 0
40
Nedap extened protocol 2400 Baud
21
RS485
Bias on - no. of breaks 0
41
Nedap extened protocol 9600 Baud
22
RS485
Bias off - no. of breaks 2
42
Nedap extened protocol 19200 Baud
23
RS485
Bias on - no. of breaks 2
43
Nedap extened protocol 38400 Baud
24
RS485
Bias off - no. of breaks 4
44
RS485
Bias on - no. of breaks 4
45
RS485
Bias off - no. of breaks 6
46
RS485
Bias on - no. of breaks 6
47
RS485
Bias off - no. of breaks 8
48
RS485
Bias on - no. of breaks 8
49
RS232 with Texas Instruments protocol*
RS232
20
Texas Instruments protocol
10
*Serie 2000 reader systems ASCII protocol, 9600 baud, 8 databits, no parity, 1 stopbit
How to use the display and push button
Scroll down
press button short
Select
press button until blinking
Change and store
select item to change, open item by pressing till blinking, change by pressing
short, store by pressing to blinking
Check a setting
select the item to check, press until blinking, first value shown is actual setting
Leave without saving
press button untill display blanks
Return to main menu
anywhere in the menu, press button untill display blanks
It is possible some program states are shown during operation.