Nedap Smart Deactivator Manual Download Page 9

9

6  Appendix 1

02

Deactivator Antenna 265x265

01

Deactivator Antenna 265 x 265 (cable length 1600 mm)

GROENLO 

THE NETHERLANDS

Copyright  © by  N.V. Nederlandsche Apparatenfabriek NEDAP. No part of this drawing may be 
reproduced or distributed in any form or by any means, or stored in a data base or retrieval system 
without the prior written permission of NEDAP.

article no

date

rev

dsgn

page

drawing

quick reference : antenna 265x265

: 27 February 2014 12:08 PM

: CB

: A

: 1 of 1

: T9741704-45.01

: 9741704

Table

Bottom mount

4x , not included

 150 

  4,5 (4x) 

 150 

 265 

 265 

 150 

  4,5 (4x) 

 150 

 265 

 265 

Summary of Contents for Smart Deactivator

Page 1: ...Smart Deactivator Manual UL manual smart deactivator according to ul regulations SMART DEAC Mounting SMART DEAC Wiring Appendix 1 Quick Reference...

Page 2: ...ctrical and electronic equipment falling under Annex IA of Directive 2002 96 EC provided the equipment concerned is not part of another type of equipment that does not fall within the scope of this Di...

Page 3: ...3 Table of content 1 Introduction 4 2 System overview 5 3 Installation instructions 6 4 Regulatory declaration 7 5 Specifications SMART DEAC 8 6 Appendix 1 9...

Page 4: ...ivator advantages are 1 Constant optimal deactivation distance independent of the tag frequency between 7 2 8 8 MHz 2 Deactivation behavior programmable with switches 3 Detect only Mode 4 Deactivation...

Page 5: ...cs 9937676 3 Antenna including cable Model SDA 265x265 9564101 or Model DAPL 275x275 9911537 4 RS485 connection to communicate with the SMART DEAC 5 Input for functionality to be defined 6 Output for...

Page 6: ...utput voltages will be 12Vdc or less The inputs may only be connected to class2 powered system The SMARTDEAC must be mounted on a solid nonflammable surface using all mounting holes and proper mountin...

Page 7: ...equipment has been tested and found to comply with the limits for a class B digital devices pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harm...

Page 8: ...0 35 A 0 7 A 264 VAC 90 VAC Line Frequency 47 Hz 50 60 Hz 63 Hz Operation Voltage Power 3 W 230 VAC 50Hz Regulations Safety approvals of the Power Adapter cULus according to UL CSA 60950 1 CB accordi...

Page 9: ...rt of this drawing may be reproduced or distributed in any form or by any means or stored in a data base or retrieval system without the prior written permission of NEDAP article no date rev dsgn page...

Page 10: ...ng T9937 676 1x Smart Deactivator including power supply Smart Deactivator 1x Antenna connector set 05 Beeper sound volume 04 Connect to power 100 240V deactivation detection 06 Beeper sound Standard...

Page 11: ...itivity Software 6 4 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Standard mode Line Termination RS485 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Detect only mode 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Output after...

Page 12: ...parallelweg 2d nl 7141 dc groenlo the netherlands t f e i 31 0 544 471555 31 0 544 465814 info rs nedap com www nedap retail com 2014 v1...

Reviews: