NED
UME-0027-03 XCM6040SAT2
27
Multi-slope time setting
mst
0 to 511
0 to 511 0 to 511
Set the timing aspect of the
vertex of the multi-slope function
VAL1<=VAL2<=VAL3 i.e. when
using 4 slopes, select values
such that VAL2/VAL1 and
VAL3/VAL2 work out to the same
result. Moreover, the result
should be less than 10.
Programmable Exposure Time
=
VAL2
÷
{26666667
÷
(16
x
2
^
VAL1)}
Exposure-Readout Time
=
VAL1
÷
{26666667
÷
(16
x
2
^
VAL1*)} The VAL1* is VAL1
of Programmable Exposure Time item.
4.1.5 Memory Setup Values (Factory Settings)
The memory setup values (factory settings) are shown below.
Table 4-1-5-1 Memory Setup Values (Factory Settings)
Control Item
CMD VAL1 VAL2
VAL3
Control Description
Analog Gain
gax
0
x1(0dB)
Digital Gain
gdx
0
x1
Digital Offset
odx
0
0DN
(8bit)
Exposure Mode
inm
0
Free Run
Programmable
Exposure
Time
int
1
61
73.2
μs
(Dividing=1
、
Counter=61)
Output Signal Setting 1
voa
0
0
8bit, 6144pixels
Output Signal Setting 2
voc
0
Linear
Test Pattern
tpn
0
OFF
Pixel Correction Setting
shc
1
900
Factory White Correction
Correction Level 900DN (10bit)
Operation Status Readout
pad
0
0
μs
Scanning Direction
rev
0
Forward
:
0
Multi-slope signal setting
msl
0
5
10
3 Slope settings
Multi-slope time setting
mst
0
1
10
3 Slope settings