NED
RMSL8K76CP/RMSL6K76CP/RMSL4K76CP UME-0094-02
26
4 Camera Control
The camera can be controlled by the frame grabber board through the camera
’s
control registers. The camera supports GenICam, and so can be easily controlled by
a GenICam-compatible frame grabber. The camera control software which came
with your frame grabber should be used for camera control.
Once the camera settings have been made and saved, the camera will operate
without further setting.
4.1 Flow of Camera Control
4.1.1 GenICam overview
⚫
The camera control register information is saved inside the camera (XML file).
⚫
The frame grabber board reads the XML file during Discovery, and acquires the
register information.
⚫
Camera control is enabled after Discovery.
Please check your frame grabber’s manual for how to perform device discovery.
4.1.2 Camera Control registers
Various settings (features) of this camera correspond to GenICam SFNC 2.3. Please
set with the software attached to the frame grabber board.
The commands used in this camera are as shown in Table 4-1-2-1.
Table 4-1-2-1 List of Camera Control Registers
Features Name
R/W
VAL
< factory settings >
Control Description
Category : Device Information
Device User ID
R/W
(ASCII code)
<0x00>
User define ASCII code.
ASCII code is up to 15 characters.
The last of ASCII code is
“NULL(0x00)”.
DeviceTemperatureSelector
RW
Mainboard /
Subboard
Select temperature measurement location
Mainboard
:
Surrounding of FPGA
Subboard
:
Internal of FPGA
DeviceTemperature
R
Display the temperature inside (
℃
)
Mainboard
:
MAX75
℃
Subboard
:
MAX90
℃