Selecting the Best Location for Proper Installation
2.3.1
Selecting the KSU Installation Site
When a site is selected for the installation of the KSU the
following conditions should be considered to ensure proper
installation.
✆
KSUs are normally wall mounted to protect against
accident or flooding.
✆
The KSU should not be located directly beneath
pipes. Should leaks or condensation occur, damage
could be caused to the Xen system equipment.
✆
The area where the KSU is located must be free of
corrosive and inflammable gases, excessive chemical
or industrial dusts, and other materials that could
cause a hazard to personnel or to the proper
functioning of the equipment.
✆
The operating ambient temperature and humidity
must be within the limits specified in 4.2.2
Environmental Conditions in Chapter 2 System
Specifications.
✆
The operation of the system is virtually noiseless and
allows wide selection of installation sites. Care should
be taken to ensure the KSUs do not present a hazard
to office traffic. To minimize cabling costs, a
centralized location should be chosen.
✆
The KSU must be located at a site where it can easily
be connected to a dedicated AC power source.
✆
Connect the KSU only to a dedicated AC receptacle
that is not being used for any other devices such as
computers, copiers, or facsimile machines. Ensure
that the AC outlet is properly grounded.
✆
Avoid installing the KSU in the vicinity of a radio
receiver.