1 - 376
CO Line Ringing Pattern by Telephone or CO Selection
NEC Business Solutions Ltd
Xen Master & Xen Axis
A
6
-324000-
642-
02 - Release 6.0
May 20
03
4-57
System Mode
4
Submode
—
Data No.
57
PC Programming
a
+BTT
CO Line Ringing Pattern by
Telephone or CO Selection
General Description
Use this memory block to select if CO or Telephone is to have ring pattern.
Display
Settings
LK 1
LK 2
LK 3
LK 4
The shaded area indicates the default setting.
CO
Telephone
LK 5
LK 6
LK 7
LK 8
Programming Procedures
1
Go off-line.
2
Press LK4 +
EG
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change data option
Note:
Use the following to change option:
R
to move to the next Tel Port No.
Default Values:
CO
4
Press
N
to write the data.
5
Press
P
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
CO Line Ringing Pattern Selection for CO/PBX Line Mode
CO Ringing Pattern Selection for Telephone Mode
N
1. This memory block is applicable for main software Release 4.0 and above.
0 1 / 5 7 : R N G P R I
C O
T I M E
D I S P L A Y
Data
No.
Tel Port
No.
(01~99)
A0~C0
Setting
Data
Title