Tandem Transfer Automatic Disconnect Timer Selection
1 - 147
Programming Manual
May 2003
A6-
324000-6
42-02 -
Release 6.0
May 2003
1-4-00
System Mode
1
Submode
4
Data No.
00
PC Programming
a
+AT
Tandem Transfer Automatic
Disconnect Timer Selection
General Description
Use this Memory Block to specify maximum time before the system automatically
disconnects a Trunk-to-Trunk connection.
Display
Settings
LK 1
LK 2
LK 3
LK 4
The shaded area indicates the default setting.
30 min.
1 hr.
2 hr.
3 hr.
LK 5
LK 6
LK 7
LK 8
Programming Procedures
1
Go off-line.
2
Press LK1 + LK4 +
KK
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data
option or enter the time required in minutes
Default Values
060 min
Setting Data
000~999 (Software Version 2.xx or later)
4
Press
N
to write the data.
5
Press
P
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
Refer to Chapter 2 Guide to Feature Programming
N
This block is used for Direct Inward System Access (DISA), Trunk-to-Trunk Transfer, Call Forward - Off Premise, and Tie
line tandem features.
0 0 : A U T O
D I S
0 6 0
T I M E
D I S P L A Y
Data
No.
Title
Setting
Data