![NEC VT695 Control Commands Download Page 32](http://html1.mh-extra.com/html/nec/vt695/vt695_control-commands_3901456032.webp)
DATA03 Projector status
00H : Idling
01H : Power On
DATA04 Cooling processing
00H : No execution(Normal condition)
01H : During execution
DATA05 Power On/Off processing
00H : No execution(Normal condition)
01H : During execution
DATA06 Status of operation
00H : Idling
04H : Power On
05H : Cooling
06H : Idling(Error occurrence)
Other than above : (nondisclosure)
Internal use of code during a state transition period
DATA07 PC Card insertion
00H : Not inserted
01H : Inserted
DATA08 USB Mouse connection
00H : Not connected
01H : Connected
DATA09 .. 16 Reserved
Response: At the time of a failure
A0H 85H 01H xxH 02H DATA01 DATA02 CKS
(*1) (*2) (*4) (*3)
078-3. INPUT STATUS REQUEST
**********************************************************************
Function:
This command acquires the status of input signal of the projector.
Command:
00H 85H 00H 00H 01H 02H 88H
Response: At the time of a success
20H 85H 01H xxH 10H DATA01 .. DATA16 CKS
(*1) (*2) (*3)
Data Portion Contents
-------------------------------------------------------------------
DATA01 Selecting signal processing
00H : No execution(Normal condition)
01H : During execution
DATA02 Signal number( Entry list number - 1 )
0 .. 199