CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 37 –
NWA-008847-001 Rev.3.0
a6ch1001.fm
(3) The following information is stored and can be displayed on the MAT or the CAT using a memory
dump command in hexadecimal format:
• Program address where an endless loop has occurred
• Last initialization time for main program
• Last initialization time for firmware program
• The reason for initialization (power-on,
RESET
key, endless loop, rotary switch, command from
MAT or CAT)
(4) The PBX has a built-in patrol program that monitors the status of all connected devices. Additionally,
when no response or an invalid response from a device is received, this program stores in memory
the slot number of that device. From the MAT or the CAT, a maintenance person can read the slot
number of any device which does not respond to the main processor or provides an illegal status to
the main processor.
Programming Procedure
No programming is required.
Operating Procedure
(1) Station Status Information
Operation:
For the meaning of status code, see
DE
+
F50>
F50
ST
COMMAND=
DE
+
XXXXXXXX : XX XX XX XX
0 + X-XXXXXXXX
(Station No.)
or
0 + FX-FXXXXXXXX
(D
term
No.)
Status Code of the designated A3
Status Code of the designated A2
Status Code of the designated A1
Status Code of the designated Address
Designated Address
JULY/01/2006
DIAGNOSTICS
Summary of Contents for UNIVERGE NEAX 2000 IPS
Page 1: ...NWA 008847 001 ISSUE 3 0 Maintenance Manual...
Page 10: ...iv NWA 008847 001 Rev 3 0 a6toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Page 124: ...114 NWA 008847 001 Rev 3 0 a6ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 244: ...234 NWA 008847 001 Rev 3 0 a6ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 262: ...252 NWA 008847 001 Rev 3 0 a6ch3001 fm THIS PAGE LEFT BLANK INTENTIONALLY...