– 882 –
NWA-008844-001 Rev.5.0
91ch3009.fm
COMMAND CODE TITLE:
BILLING SYSTEM DATA ALL CLEAR FOR
PN-AP00-B/PN-AP00-D WITH MRCA PROGRAM
DD99
FUNCTION:
This command is used to clear all the system data for billing and to load the initial data when using PN-
AP00-B/PN-AP00-D with MRCA program.
[Series 3300]
PRECAUTION:
To load the initial data of AP00, follow the STEPs below.
STEP 1:
Assign AP number (XX) to PN-AP00-B/PN-AP00-D (AP00) card by CM05 Y=0>XX:
04.
STEP 2:
Mount the AP00 card to the AP slot.
STEP 3:
Make the AP00 card OFF LINE by switch setting as shown below.
STEP 4:
Clear all billing system data by CMDD99>0000: CCC from the MAT.
The initial data are loaded by this operation.
STEP 5:
Make the AP00 card ON LINE by switch setting as shown below.
STEP 6:
Flip the MB switch on the AP00 card to ON (UP position), then OFF (DOWN position).
AP OFF LINE
SW1
ON
SW1-4 should be set as follows;
ON : The AP No. is 04-15
OFF: The AP No. is 20-31
4
3
2
1
: Position to be set
SW1
ON
SW1-4 should be set as follows;
ON : The AP No. is 04-15
OFF: The AP No. is 20-31
4
3
2
1
: Position to be set
JULY/01/2006
CMDD99
Summary of Contents for UNIVERGE NEAX 2000 IPS
Page 1: ...NWA 008844 001 ISSUE 5 0 Command Manual ...
Page 24: ... viii NWA 008844 001 Rev 5 0 91toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006 ...
Page 46: ... 22 NWA 008844 001 Rev 5 0 91ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY DECEMBER 02 2005 ...
Page 66: ... 42 NWA 008844 001 Rev 5 0 91ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY DECEMBER 02 2005 ...
Page 908: ... 884 NWA 008844 001 Rev 5 0 91ch3009 fm THIS PAGE LEFT BLANK INTENTIONALLY JUNE 01 2007 ...
Page 988: ... 964 NWA 008844 001 Rev 5 0 91ch4001 fm THIS PAGE LEFT BLANK INTENTIONALLY DECEMBER 02 2005 ...
Page 1012: ... A24 NWA 008844 001 Rev 5 0 91apa001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...