– 100 –
CHAPTER 2
Operations of SV8500 Server
8.1.4
How to Control Switching Block
This section explains how to control switching block, which consists of the follow-
ing cards:
•
TSW (1-IMG: PH-SW10-A, etc. 4-IMG: PH-SW12)
•
MUX (PH-PC36)
•
DLKC (PH-PC20 for 4-IMG only)
•
PLO (PH-CK16-D, etc for 4-IMG only)
Perform the required system changeover by using the CMOD command or by operating the related key on
the GT/PLO card. Refer to the tables below.
Changeover of Switching Block (1-IMG)
TYPE
OPERATIONS
REMARKS
CMOD
(recommended)
Use CMOD command (See
- TSW ACT lamp goes off on the TSW card that
was originally placed in ACT mode.
- TSW ACT lamp lights green on the TSW card that
was originally placed in STBY mode.
Key Operation
- Set TSW MBR key upward on the TSW that is placed in ACT.
- Return TSW MBR key downward on the TSW.
-TSW ACT lamp lights red and MUX ACT lamp
goes off on the TSW card.
-TSW ACT lamp goes off.
- TSW ACT lamp lights green on the TSW card that
was originally placed in STBY mode.
Changeover of Switching Block (4-IMG)
TYPE
OPERATIONS
REMARKS
CMOD
(recommended)
Use CMOD command (See
- TSW ACT lamp goes off on the TSW card that was originally placed
in ACT mode. OPE lamp also goes off on DLKC card that was original-
ly placed in ACT mode.
- TSW ACT lamp lights green on the TSW card that was originally
placed in STBY mode. OPE lamp also lights green on DLKC card that
was originally placed in STBY mode.
Key Operations
- Set MBR key upward on the ACT GT.
- Return MBR key downward on the GT.
- TSW ACT lamp goes off on the TSW card that was originally placed
in ACT mode. OPE lamp also goes off on DLKC card that was original-
ly placed in ACT mode.
- TSW ACT lamp lights green on the TSW card that was originally
placed in STBY mode. OPE lamp also lights green on DLKC card that
was originally placed in STBY mode.
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
Be sure to use “TSW MBR” key on the TSW-ACT TSW card. If “TSW MB” key is operated
before operating “TSW MBR” key on the TSW-ACT TSW card, the card will be reset. During
this initialization, all channels on the card will be placed in MB status, disconnecting all active
WARNING
Be sure to use “MBR” key on the ACT GT card. If “MB” key is operated before operating
“MBR” key on the ACT GT card, the card will be reset. During this initialization, all channels
that are related to this card will be placed in MB status, disconnecting all active calls.
WARNING
Summary of Contents for SV8500
Page 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Page 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Page 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Page 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Page 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Page 973: ......
Page 974: ...Printed in Japan 0901 020...
Page 975: ......