26.9 Version Upgrade
This section describes the procedure to upgrade an SR-MGC(S) program. Take anti-static
measures to work on it.
SR-MGC(S) Version Upgrade Procedure
For details on hardware information, see
To upgrade an SR-MGC(S) program from FP85-107 S4 to FP85-108 S5, EXP MEM-2GB SET is required.
Check the information in the guide accompanying EXP MEM-2GB SET before starting the procedure below.
STEP 1: Turn off an SR-MGC(S).
Perform the SINZ command to shutdown an SR-MGC(S); make sure that the ONLINE lamp
goes off; turn off power of the SR-MGC(S).
STEP 2: Unplug a LAN cable from the SR-MGC(S).
Unplug a LAN cable from the LAN1 connector on the front panel of the SR-MGC(S).
STEP 3: Remove an old CF card from the SR-MGC(S).
Remove an existing CF card from the CF slot on the front panel of the SR-MGC(S).
STEP 4: Insert a new CF into the SR-MGC(S).
Insert a CF card supplied for the version upgrade into the CF slot on the front panel of the SR-
MGC(S).
STEP 5: Expand the memory and check the memory size. (Upgrade from FP85-107 S4 or earlier ver-
sion to FP85-108 S5 or later version)
For the memory expansion procedure, see the guide accompanying EXP MEM-2GB SET.
Note:
This step is not required for upgrading an SR-MGC(S) program other than from FP85-107 S4 or earlier
version to FP85-108 S5 or later version. After this step is finished, skip
.
STEP 6: Turn on the SR-MGC(S).
Turn on power of the SR-MGC(S), where its operation is the following: booting up the system;
reading default office data.
Note:
The IP address set in default office data is 172.16.253.0/16.
STEP 7: Check the lamps.
Make sure that lamp states are as follow.
PWR: ON (green)
ONLINE: Slow flash (green)
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
Summary of Contents for SV8500
Page 1: ...Peripheral Equipment Description NWA 041680 001 ISSUE 12 0 FP85 110 S7 ...
Page 110: ...VOL 1 50 CHAPTER 1 DEVICES REQUIRED TO BUILD NETWORK Network Services List Box Example ...
Page 253: ...VOL 2 xiv TABLE OF CONTENTS CONTINUED Page ...
Page 292: ...VOL 2 39 Zone Transceiver ZT LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp ...
Page 1854: ...VOL 2 1601 MG SIP96 Port Settings tab opens Set the values as the following figure shows ...
Page 2721: ...VOL 3 234 CHAPTER 2 TERMINAL RELATED DEVICES Mounting of BATT BOX ASSEM Cover BATT BOX ASSEM ...
Page 3113: ...VOL 3 626 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3114: ...VOL 3 627 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3115: ...VOL 3 628 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3118: ...VOL 3 631 CHAPTER 4 CONFIGURATION SETUP b English Sm Lower case ...
Page 3119: ...VOL 3 632 CHAPTER 4 CONFIGURATION SETUP c Turkish Bg Upper case d Turkish Sm Lower case ...
Page 3120: ...VOL 3 633 CHAPTER 4 CONFIGURATION SETUP e Russian Bg Upper case f Russian Sm Lower case ...
Page 3438: ...Printed in Japan 1307 120 ...