- 120 -
Changing Port Topology
After completing login to the console of the FC Switch Module, change the topology of external
ports on the FC Switch Module according to the procedure below. (The port topology must always
be set.)
Setting at shipment from factory
The port topology (Locked G_Port) is set as follows when an FC Switch Module is shipped from the
factory.
External ports:
ON (Valid: only fabric devices connectable)
Internal ports:
·· (Invalid: Select Auto as the topology.)
The port topology of an FC Switch Module must be set to be the same as
the port topology of fibre channel devices connected to the FC Switch
Module. If the port topologies are different, the connected fibre channel
devices cannot link up to the FC Switch Module. For the port topology of
each fibre channel device to be connected to an FC Switch Module, refer to
the User’s Guide of the fibre channel device.
1.
Type "portcfgshow" on the console screen.
Any commands used on the switch console should be specified with
lowercase letters.
2.
The current port settings appear.
WH040000350:admin> portcfgshow
Ports of Slot 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
------------------+--+--+--+--+----+--+--+--+----+--+--+--+----+--+--+--
Speed 4G 4G 4G 4G 4G 4G 4G 4G 4G 4G 4G 4G 4G 4G 4G 4G
Trunk Port ON .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Long Distance .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
VC Link Init .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked L_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked G_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Disabled E_Port .. ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
ISL R_RDY Mode .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
RSCN Suppressed .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Persistent Disable .. .. ON ON .. ON ON ON ON ON ON ON ON ON ON ON
Ports of Slot 0 16 17 18 19 20 21 22 23
------------------+--+--+--+--+----+--+--+--
Speed 4G 4G 4G 4G 4G 4G 4G 4G
Trunk Port .. ON ON ON ON ON ON ON
Long Distance .. .. .. .. .. .. .. ..
VC Link Init .. .. .. .. .. .. .. ..
Locked L_Port .. .. .. .. .. .. .. ..
Locked G_Port .. ON ON ON ON .. .. ..
Disabled E_Port ON .. .. .. .. .. .. ..
ISL R_RDY Mode .. .. .. .. .. .. .. ..
RSCN Suppressed .. .. .. .. .. .. .. ..
Persistent Disable ON .. .. .. .. .. .. ..
where AN:AutoNegotiate, ..:OFF, ??:INVALID.
WH040000350:admin>
The port status display also includes the information on the ports
unavailable to N8406-019. However, this is not an error.
Summary of Contents for SIGMABLADE N8406-019
Page 2: ...2 N8406 019 N8406 020 FC N8406 019 N8406 020 FC SIGMABLADE SIGMABLADE...
Page 6: ...6...
Page 8: ...8 OFF NF9330 SF02 SFP 1 20cm SFP...
Page 9: ...9 SIGMABLADE...
Page 12: ...12 SIGMABLADE SIGMABLADE SIGMABLADE...
Page 14: ...14 N8406 019 N8406 020 FC Windows 3 6...
Page 16: ...16 SIGMABLADE...
Page 18: ...18...
Page 24: ...24 1 ID or ID 3 Status Status 3 ACT 1 1 Status...
Page 25: ...25 Status LED LED SFP SFP Fibre Channel 1 Disable 0 25 Speed LED LED 1Gbps 2Gbps 4Gbps 1Gbps...
Page 27: ...27 4 SIGMABLADE SFP FC SFP FC FC FC FC...
Page 29: ...29 SIGMABLADE SIGMABLADE SIGMABLADE SIGMABLADE SIGMABLADE SIGMABLADE SIGMABLADE...
Page 30: ...30 SIGMABLADE SIGMABLADE SIGMABLADE 10 Fibre Channel SIGMABLADE SIGMABLADE CPU Fibre Channel...
Page 31: ...31 SIGMABLADE FC FC FC FC FC FC SFP SFP 4 2 SFP SFP...
Page 32: ...32 SIGMABLADE SIGMABLADE SIGMABLADE SIGMABLADE SIGMABLADE FC 4...
Page 34: ...34 SFP SFP SFP SFP SFP N8406 FC NF9330 SF02 SFP N8406 FC...
Page 35: ...35 4 3 FC PASSWORD Domain ID Principal Selection Mode FC...
Page 65: ...65 1 Principal Principal Principal Selection Mode 2 1 1 Fabric I O 2 2 2 Fabric I O 1 2 1 2...
Page 66: ...66 3 1 Fabric I O 2 2 2 Fabric I O 2 3 2 3 1 1...
Page 67: ...67 3 3 1 Fabric I O 4 1 Fabric I O 2 3 1 2 3 4 1...
Page 68: ...68 2 2 2 Fabric I O 3 4 1 Fabric I O 2 3 4 1 2 3 4 1...