5
■
Drop test
●
Onto plywood
While turned off, the device is dropped once from a height of 90 cm onto plywood on each
face, side and corner for a total of 26 drops.
●
Onto concrete
While turned off, the device is dropped once from a height of 90 cm onto concrete on each
face for a total of 6 drops.
■
Vibration test
●
Sine wave vibration (vibration time 56 minutes)
While turned on, the device is subjected to vibration at the following frequencies: 10 – 55
Hz: 0.075 mm (0-P), 55 Hz – 500 Hz: 9.8 m/s2 (0-P).
While turned off, the device is subjected to vibration at the following frequencies: 10 – 55
Hz: 0.15 mm (0-P), 55 Hz – 500 Hz: 19.6 m/s2 (0-P).
●
Random wave vibration (vibration time 60 minutes)
While turned off, the device is subjected to vibration at the following frequencies: 20 Hz
–
1000 Hz: 0.04 G2.Hz, 1000 Hz
–
2000 Hz: -6dB/Octave.