42
04. VOLUME Gain Data
Function
The external control equipment changes the VOLUME gain data of the PlasmaSync 5000W.
Transmission Data
DFH 80H
60H
7FH
03H
DATA00
DATA01
DATA02
CKS
DATA00: USER SOUND Gain Flag
05H
DATA01: VOLUME Gain Flag
01H
DATA02: VOLUME Gain
00H: Step 0
0AH: Step 10 (Default)
2AH: Step 42
ACK
7FH
60H
80H
7FH
02H
DATA00
DATA01
CKS
DATA00: USER SOUND Gain Flag
05H
DATA01: VOLUME Gain Flag
01H
05. SCREEN MODE Select
Function
The external control equipment switches the screen mode of the PlasmaSync 5000W.
Transmission Data
DFH 80H
60H
51H
01H
DATA00
CKS
DATA00
02H : STADIUM
03H : ZOOM
04H : NORMAL
05H : FULL
06H : TRUE
ACK
7FH
60H
80H
51H
01H
DATA00
CKS
DATA00
02H : STADIUM
03H : ZOOM
04H : NORMAL
05H : FULL
06H : TRUE
06. AUDIO Mute On
Function
The external control equipment switches on AUDIO Mute of the PlasmaSync 5000W.
Transmission Data
9FH
80H
60H
3EH
00H
CKS
ACK
3FH
60H
80H
3EH
00H
CKS
07. AUDIO Mute Off
Function
The external control equipment switches off AUDIO Mute of the PlasmaSync 5000W.
Transmission Data
9FH
80H
60H
3FH
00H
CKS
ACK
3FH
60H
80H
3FH
00H
CKS