
©NEC Display Solutions, Ltd. 2014-2020
33
3.16
[ 037-3. FILTER USAGE INFORMATION REQUEST ]
Gets filter usage information such as usage time.
Command
03h 95h 00h 00h 00h 98h
Response
When the command succeeds
23h 95h
<ID1>
<ID2>
08h
<DATA01>
-
<DATA08>
<CKS>
Data part
Item
Description
DATA01 - 04
Filter usage time (seconds)
DATA05 - 08
Filter alarm start time (seconds)
Information
If no time is defined, "-1" is returned.
When the command fails
A3h 95h
<ID1>
<ID2>
02h
<ERR1>
<ERR2>
<CKS>